多个类型为X357_KPM6V3T8ATE的磁盘在短时间内出现故障
适用场景
磁盘类型 X357_KPM6V3T8ATE
问题描述
- 数据中心的高温环境条件
- 多个驱动器出现故障
- 发现带有以下SCSI错误的AutoSupport事件消息:
0x0x2 - 0x0x4 0x0x80
[scsi.debug:debug]: (EMS parameters: debug_string="shm_setup_for_failure disk 0a.01.10 (S/N 22B0A0LJTARJ) error 80000h")
[raid.disk.predictiveFailure:error]: Disk 0a.01.10 Shelf 1 Bay 10 [NETAPP X357_KPM6V3T8ATE NA50] S/N [22B0A0LJTARJ] UID [xxxxxx] reported a predictive failure and it is prefailed; it will be copied to a spare and failed ...
[scsi.cmd.checkCondition:error]: Device 0a.01.10: Check Condition: CDB 0x28:dca05400:0200: Sense Data SCSI:not ready - (0x0x2 - 0x0x4 0x0x80 0x0x0)(0). ...
[raid.config.filesystem.disk.failed:error]: File system Disk 0d.01.10 Shelf 1 Bay 10 [NETAPP X357_KPM6V3T8ATE NA50] S/N [22B0A0LJTARJ] UID [xxxxxx] failed. ...