跳转到主内容

在ONTAP中使用不正确的磁盘故障语法时、多个NVMe磁盘失败

Views:
10
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009年75 3668</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP
  • NVMe磁盘

问题描述

  • NVMe磁盘的路径ID (例如e5a.10.2.8)及其磁盘ID (例如1.10.8)与ONTAP使用的路径ID不同。
  • 磁盘故障需要磁盘ID、而不是路径。
  • 如果使用路径使磁盘出现故障、则该磁盘应出现故障:
storage disk fail -disk e5a.10.2.8
Error: Disk "e5a.10.2.8" does not exist.
  • 但是、如果不使用带有 <> 符号的路径、则ONTAP会将这些符号解释为"大于"和"小于"、从而导致多个磁盘在此时发生意外故障:
storage disk fail -disk <e5a.10.2.8>
Success: 32 entries were acted on.
  • 注意: 如果您要继续对每个磁盘运行命令、ONTAP会提示您、并且只有在问题解答每个提示符输入yes后、多个驱动器才会出现故障。
  • -i 使用上述语法添加参数将立即使磁盘出现故障、从而导致RAID组降级到其RAID故障阈值

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.