适用场景

  • 所有 FAS 系统
  • 所有AFF系统

问题描述

  • 与磁盘堆栈的通信出现问题或丢失
  • EMS报告以下信息:
Mon Oct 11 07:58:05 -0600 [node-01: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
  • 一个或两个节点会在Sysconfig -a中报告混合路径配置
 NetApp Release 9.7P9: Thu Nov 5 20:15:56 EST 2020 System ID: 0XXXXXXXXX (node-01); partner ID: 0XXXXXXXXX (node-02) System Serial Number: XXXXXXXXXXXXXX (node-01) System Rev: C1 System Storage Configuration: Mixed-Path 
  • 已禁用SAS端口、但已安装缆线
     slot 2: SAS Host Adapter 2b (PMC-Sierra PM8001 rev. C, SAS, <OFFLINE (soft)>) MFG Part Number: USI 6086-000010-07 rev. MP V4.13 Part number: 111-00341+G1 Serial number: xxxxxxxxxxx Date Code: 20150817 Firmware rev: 01.12.09.00 Base WWN: 5:00e004:xxxxxxx:xx Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled QSFP Vendor: Amphenol QSFP Part Number: X6558-R6+A0 QSFP Type: Passive Copper 2m ID:00 QSFP Serial Number: xxxxxxxxxxxxxx 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.