适用场景

  • 所有 FAS 和 AFF 型号
  • ONTAP 9
  • V 系列后端

问题描述

多磁盘崩溃会导致节点重新启动。EMS 中显示以下错误消息:
 
EMS 错误消息:
 
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: raid.vol.failed:notice]: Aggregate aggr1: Failed due to multi-disk error.
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf -, Bay -, Model [VRAID], S/N [6006016015603C0044145347182DE8110]
Sat Sep 04 15:56:53 EDT [cluster-01: raid_disk_thread: raid.disk.unload.done:info]: Unload of Disk NanoFCS01B:34.126L26 Shelf - Bay - [DGC VRAID 0533] S/N [6006016015603C0044145347182DE811] UID [60060160:15603C00:44145347:182DE811:00000000:00000000:00000000:00000000:00000000:00000000] has completed successfully
Sat Sep 04 15:56:53 EDT [cluster-01: config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr1: raid volfsm, fatal disk error in RAID group with no parity disk. raid type raid0 Group name plex0/rg1 state NORMAL 1 disk failed in the group. Disk NanoFCS01B:34.126L26 Shelf - Bay - [DGC VRAID 0533] S/N [6006016015603C0044145347182DE811] UID [60060160:15603C00:44145347:182DE811:00000000:00000000:00000000:00000000:00000000:00000000] error fatal disk error..

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

This is an internal KB article and its content should not be copy/pasted and shared with people outside of NetApp. Always seek Duty Manager authentication of caller for password reset requests. If you need further assistance post a question in Knowledge Xchange