更换后缺少磁盘
适用场景
- ONTAP
- 磁盘更换
- 磁盘架托架
问题描述
- 故障磁盘的自动案例:
DSK*FLT:Disk /aggregate/plex0/rg0/0a.0.0 Shelf 0 Bay 0 [NETAPP X123_ABCD012345678 NA00] S/N [AB123456]- 已更换磁盘、但LED无活动
- 日志中缺少驱动器:
Mon Jan 01 12:28:14 0300 [node_name: dmgr_thread: raid.disk.missing:info]: Disk /aggregate/plex0/rg0/0a.0.0 Shelf 0 Bay 0 [NETAPP X123_ABCD012345678 NA00] S/N [AB123456] UID [...] is missing from the system
Mon Jan 01 12:28:14 0300 [node_name: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggregate/plex0/rg0/0a.0.0 Shelf 0 Bay 0 [NETAPP X123_ABCD012345678 NA00] S/N [AB123456] UID [...] is missing.
Mon Jan 01 12:28:14 0300 [node_name: config_thread: raid.rg.degraded:notice]: : Raid group /aggregate/plex0/rg0 is degraded
Mon Jan 01 12:28:55 0300 [node_name: config_failed_disk: callhome.fdsk. missing:error]: Call home for FILESYSTEM DISK MISSING
- 报告磁盘架托架为空:
Shelf name: 0a. shelf0Shelf id: 0Channel: 0aModule: AShelf UID: aa:bb:cc:dd:ee:ff:00:11Shelf S/N: ABCD0123456789Term switch: N/AShelf state: ONLINEModule state: OKPartial Path Link Invalid Running Loss Phy CRC PhyDisk Port Timeout Rate DWord Disparity Dword Reset Error Change ...----------------------------------------------------------------...... [ 3 ] EMPTY 7 NA 0 0 0 0 0 4 ...