MetroCluster HA 互连端口 e1a 关闭
适用于
- ONTAP 9
- MetroCluster IP
- 使用 100 GbE QSFP28 光模块的 HA 互连端口
问题
- EMS 报告重复的 HA 互连关闭事件
node-02 ERROR ic.HAInterconnectDown: HA interconnect: Interconnect down for 606 minutes: link0 downnode-02 ERROR ic.HAInterconnectDown: HA interconnect: Interconnect down for 546 minutes: link0 down
- 为 HA 互连端口离线生成的 Call Home 警报
node-02 ALERT callhome.hainterconnect.down: Call home for HA INTERCONNECT DOWN due to link0 down.node-02 ALERT callhome.hm.alert.major: Call home for Health Monitor process nchm: MccIp_PortOfflineAlert[node-02].
- 一个节点显示 HA 互连链路断开,而配对节点仍在运行
cluster::*> system ha interconnect status show Node: node-01 Link 0 Status: up Link 1 Status: up Is Link 0 Active: true Is Link 1 Active: true IC RDMA Connection: up Node: node-02 Link 0 Status: down Link 1 Status: up Is Link 0 Active: false Is Link 1 Active: true IC RDMA Connection: up
- 未在受影响的端口上检测到 QSFP 模块
sysconfig -a slot 1: Dual 40/100G Ethernet T62100-CR e1a MAC Address: 00:07:43:xx:xx:xx (auto-unknown-fd-down) QSFP Vendor: QSFP Part Number: QSFP Serial Number: