跳转到主内容

在内部交换机 SP 或 BMC 更新期间,ONTAP 内的管理接口无法访问

Views:
32
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • AFF 和 FAS 机型

问题

  • 内部交换机更新期间,托管在同一节点 e0M 端口上的 SP 或 BMC 固件管理接口 (LIF) 会暂时不可用。
  • EMS 报告在 SP/BMC 固件升级完成后的内部交换机更新期间 e0M 端口链路断开/恢复:

[Node_01: spnr_main: sp.eth.switch.upd.start:notice]: BMC is starting Ethernet switch auto-update from 18 to 19.
[Node_01: intr: netif.linkDown:info]: Ethernet e0M: Link down, check cable.
[Node_01: spnr_main: sp.eth.switch.upd.success:notice]: BMC Ethernet switch version updated from 18 to 19.
[Node_01: intr: netif.linkUp:info]: Ethernet e0M: Link up.

  • SP-LATEST-SYSTEM-EVENT-LOG 报告 SP/BMC 固件升级完成后内部交换机更新期间 e0M 端口链路关闭/打开:

Record 2125: Mon Feb 02 01:20:38.850000 2026 [Fud.normal]: retcode 0, Firmware install successful
Record 2129: Sun Jan 01 00:00:40.682986 2017 [BMC.notice]: Running primary version 11.12
Record 2160: Mon Feb 02 01:27:00.032021 2026 [BMC.notice]: Starting Ethernet switch auto-update...
Record 2162: Mon Feb 02 01:27:34.792271 2026 [IPMI.notice]: 03b5 | 02 | EVT: 0900ffff | Wrench_Port_Up | Assertion Event, "Device Disabled"
Record 2163: Mon Feb 02 01:27:36.659701 2026 [BMC.notice]: Switch auto-updated to latest version 19
Record 2165: Mon Feb 02 01:27:40.698782 2026 [IPMI.notice]: 03b7 | 02 | EVT: 0901ffff | Wrench_Port_Up | Assertion Event, "Device Enabled"

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.