跳转到主内容

多个风扇故障会导致系统关闭

Views:
43
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008848178</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF 和 FAS
  • ONTAP 9
  • Data ONTAP 8

问题描述

系统发出风扇故障消息并导致关闭。

  • EMS 日志

Jul 16 23:22:58 [node-1:callhome.shlf.fan:EMERGENCY]: Call home for SHELF COOLING UNIT FAILED 
Jul 16 23:23:07 [node-1:monitor.fan.critical:EMERGENCY]: 2 fans have failed. Replace them to avoid overheating. If not corrected, system will shutdown in 2 minutes. 
Jul 16 23:23:37 [node-1:callhome.fans.failed:EMERGENCY]: Call home for MULTIPLE FAN FAILURE 
Jul 16 23:25:27 [node-1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed) 

  • AC_Power_Fail Asserted Deasserted 服务处理器( SP )events all 日志会反复报告错误

Record 2043: Sat Jul 17 08:03:44 2021 [IPMI Event.critical]: IPMI SEL log limit exceeded
Record 2044: Sat Jul 17 08:03:44 2021 [IPMI.notice]: fc07 | 02 | EVT: 0300ffff | AC_Power_Fail | Assertion Event, "State Deasserted"
Record 2045: Sat Jul 17 08:03:48 2021 [SP.warning]: Agent IIRQ false alarm
Record 2046: Sat Jul 17 08:04:06 2021 [IPMI Event.critical]: IPMI SEL log limit exceeded
Record 2047: Sat Jul 17 08:04:06 2021 [IPMI.notice]: fd07 | 02 | EVT: 0301ffff | AC_Power_Fail | Assertion Event, "State Asserted"
Record 2048: Sat Jul 17 08:04:08 2021 [IPMI Event.critical]: IPMI SEL log limit exceeded
Record 2049: Sat Jul 17 08:04:08 2021 [IPMI.notice]: fe07 | 02 | EVT: 0300ffff | AC_Power_Fail | Assertion Event, "State Deasserted"
Record 2050: Sat Jul 17 08:04:09 2021 [IPMI Event.critical]: IPMI SEL log limit exceeded
Record 2051: Sat Jul 17 08:04:09 2021 [IPMI.notice]: ff07 | 02 | EVT: 0301ffff | AC_Power_Fail | Assertion Event, "State Asserted"

  • 无法从 SPsystem sensors 输出中读取与 CPU 相关的信息。

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | na     | degrees C  | na     | na     | na     | -5.000   | 0.000
In_Flow_Temp    | 24.000    | degrees C  | ok      | 0.000    | 10.000   | 70.000   | 75.000
Out_Flow_Temp   | 23.000    | degrees C  | ok      | 0.000    | 10.000   | 82.000   | 87.000
Memory_Hot     | 0x0     | discrete   | Deasserted | na     | na     | na     | na
CPU_Hot      | 0x0     | discrete   | Deasserted | na     | na     | na     | na
CPU_Cat_Error   | 0x0     | discrete   | Deasserted | na     | na     | na     | na
CPU_Therm_Trip   | 0x0     | discrete   | Deasserted | na     | na     | na     | na
CPU_VCC      | na     | Volts    | na     | 0.708    | 0.747    | 1.348    | 1.426
CPU_1.05V     | na     | Volts    | na     | 0.892    | 0.941    | 1.154    | 1.203
CPU_VTT      | na     | Volts    | na     | 0.931    | 0.989    | 1.213    | 1.261
LM56_Temp     | na     | degrees C  | na     | 0.000    | 10.000   | 79.000   | 84.000
CPU_1.5V      | na     | Volts    | na     | 1.271    | 1.348    | 1.649    | 1.727
1G_1.0V      | na     | Volts    | na     | 0.854    | 0.902    | 1.096    | 1.154
FC_0.9V      | na     | Volts    | na     | 0.776    | 0.815    | 0.989    | 1.038
FC_1.0V      | na     | Volts    | na     | 0.854    | 0.902    | 1.096    | 1.154
USB_5.0V      | na     | Volts    | na     | 4.253    | 4.495    | 5.492    | 5.759
PCH_3.3V      | na     | Volts    | na     | 2.798    | 2.973    | 3.625    | 3.800
SASS_1.0V     | na     | Volts    | na     | 0.854    | 0.902    | 1.096    | 1.145
SASS_1.2V     | na     | Volts    | na     | 1.018    | 1.077    | 1.319    | 1.377
IB_1.2V      | na     | Volts    | na     | 1.018    | 1.077    | 1.319    | 1.37

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.