AFF A700s 上的 MPB1 传感器出现故障
适用场景
- AFF A700
问题描述
- EMS 错误消息示例:
Fri Jul 30 15:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp1) is not readable.
Fri Jul 30 15:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp1) is not readable.
Fri Jul 30 15:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp2) is not readable.
Fri Jul 30 15:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp2) is not readable.
Fri Jul 30 15:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp3) is not readable.
Fri Jul 30 15:33:31 +0200 [node_name: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
Fri Jul 30 15:34:00 +0200 [node_name: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
Fri Jul 30 15:34:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp3) is not readable.
Fri Jul 30 15:34:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp4) is not readable.
Fri Jul 30 15:34:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp4) is not readable.
Fri Jul 30 15:34:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (BridgeB1 LTemp) is not readable.
Fri Jul 30 15:34:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (BridgeB1 RTemp) is not readable.
Fri Jul 30 16:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp1) is not readable.
Fri Jul 30 16:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp1) is not readable.
Fri Jul 30 16:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp2) is not readable.
Fri Jul 30 16:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 RTemp2) is not readable.
Fri Jul 30 16:33:01 +0200 [node_name: env_mgr: monitor.temp.unreadable:error]: The controller temperature (MPB1 LTemp3) is not readable.
Fri Jul 30 16:33:31 +0200 [node_name: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
... (repeated hourly)
- HA 对中每个节点的以下传感器均显示为发生故障:
::> system node run -node * -command environment status
2 entries were acted on.
Node: netapp-a700s-1
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
---------------------------------------------------------------------------------------------------
MPB1 LTemp4 failed -- C 0 C 5 C 55 C 60 C
MPB1 RTemp4 failed -- C 0 C 5 C 55 C 60 C
Node: netapp-a700s-2
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
MPB1 LTemp4 failed -- C 0 C 5 C 55 C 60 C
MPB1 RTemp4 failed -- C 0 C 5 C 55 C 60 C
- 未报告其他温度传感器问题