  • FCP

问题

  • FC 目标端口链路 - 不稳定/关闭。
  • 以下事件记录在 EMS 上的 NetApp:

[Node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 4c with event status 1 , topology type 1, status1 0x0, status2 0x0.
[Node1: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 4c.

[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x4 for NPIV port 0. 
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0.
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 3a with event status 1 , topology type 1, status1 0x0, status2 0x0. 
[Node1: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0."


  • 可按照以下步骤隔离此问题:
    • 检查控制器端口状态的 Tx 值是否良好,如果 Tx 信号功率低,则更换 SFP。
    • 检查连接的交换机端口的 SFP 状态,如果交换机端口 Tx 功率低,则更换 SFP。
    • 如果 FC 端两侧的 SFP Tx 功率正常,但任何一侧的 SFP Rx 功率较低,则更换 FC 电缆。
    • 如果涉及配线面板,请对链路组件进行故障排除。
    • 如果两端的 Rx 信号较低,请检查两端之间的配线面板,并尝试不同的端口进行测试

示例
cluster1::> fcp adapter show -node Node1 -adapter 4c -instance
(network fcp adapter show)

Node: Node1
Adapter: 4c
Description: Fibre Channel Target Adapter 4c (Emulex LPe16000 (LPe16004), rev. 13, 16G)
Physical Protocol: fibre-channel
Maximum Speed: 16
Administrative Status: up
Operational Status: online
Extended Status: ADAPTER UP
Host Port Address: b10140
Firmware Revision: 11.2.219.4
Data Link Rate (Gbit): 16
Fabric Established: true
Fabric Name: xx:xx:xx:xx:xx:xx:xx:xx
Connection Established: ptp
Is Connection Established: true
Mediatype: ptp
Configured Speed: auto
Adapter WWNN: aa:aa:aa:aa:aa:aa:aa:aa
Adapter WWPN: bb:bb:bb:bb:bb:bb:bb:bb
Switch Port: switch1:1/88
Form Factor Of Transceiver: SFP
Vendor Name Of Transceiver: EMULEX
Part Number Of Transceiver: AFBR-57F5MZ-ELX
Revision Of Transceiver:
Serial Number Of Transceiver: AC1544J02X7
FC Capabilities Of Transceiver: 4,8,16 (Gbit/sec)
Vendor OUI Of Transceiver: 00:17:6a
Wavelength In Nanometers: 850
Date Code Of Transceiver: 15:10:26
Validity Of Transceiver: true
Connector Used: LC
Encoding Used: 64B66B
Is Internally Calibrated: true
Received Optical Power: 56.2 (uWatts)
Is Received Power In Range: true
SFP Transmitted Optical Power: 610.0 (uWatts)
Is Xmit Power In Range: true

Received Optical Power   587.2 (uWatts)
Is Received Power In Range  true
SFP Transmitted Optical Power 794.2 (uWatts)
Is Xmit Power In Range   true

交换机端口 RX/TX

RX Power:   -3.8   dBm (419.50uW)
TX Power:   -0.8   dBm (823.60 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.