由于缆线故障、在光纤通道目标HBA上检测到链路中断
适用场景
- ONTAP 9
- FCP
问题描述
- FC目标端口链路—不稳定/关闭。
EMS
NetApp上会记录以下事件:
[?] Wed Oct 14 09:22:49 MDT [host1: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 4c with event status 1 , topology type 1, status1 0x0, status2 0x0.
[?] Wed Oct 14 09:22:50 MDT [host1: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 4c.
Tue Mar 05 15:19:28 0530 [NetApp: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x4 for NPIV port 0.
Tue Mar 05 15:19:29 0530 [NetApp: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0.
Tue Mar 05 15:26:48 0530 [NetApp: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 3a with event status 1 , topology type 1, status1 0x0, status2 0x0.
Tue Mar 05 15:26:59 0530 [NetApp: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 3a has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x1a for NPIV port 0."
- 可以执行以下步骤来隔离问题描述:
- 检查控制器端口状态、如果Tx 信号 功率低、请更换SFP。
- 检查已连接交换机端口的SFP状态、如果交换机端口Tx 电源低、请更换SFP。
- 如果 两个FC端的SFP Tx功率均正常、但 任一端的SFP Rx功率均较低、请更换FC缆线。
- 如果涉及配线板、请对链路组件进行故障排除。
- 如果两端的Rx信号均较低、请 检查两者之间是否存在配线板、并尝试使用其他端口进行测试
示例:
cluster1::> fcp adapter show -node host1 -adapter 4c -instance
(network fcp adapter show)
Node: host1
Adapter: 4c
Description: Fibre Channel Target Adapter 4c (Emulex LPe16000 (LPe16004), rev. 13, 16G)
Physical Protocol: fibre-channel
Maximum Speed: 16
Administrative Status: up
Operational Status: online
Extended Status: ADAPTER UP
Host Port Address: b10140
Firmware Revision: 11.2.219.4
Data Link Rate (Gbit): 16
Fabric Established: true
Fabric Name: xx:xx:xx:xx:xx:xx:xx:xx
Connection Established: ptp
Is Connection Established: true
Mediatype: ptp
Configured Speed: auto
Adapter WWNN: aa:aa:aa:aa:aa:aa:aa:aa
Adapter WWPN: bb:bb:bb:bb:bb:bb:bb:bb
Switch Port: switch1:1/88
Form Factor Of Transceiver: SFP
Vendor Name Of Transceiver: EMULEX
Part Number Of Transceiver: AFBR-57F5MZ-ELX
Revision Of Transceiver:
Serial Number Of Transceiver: AC1544J02X7
FC Capabilities Of Transceiver: 4,8,16 (Gbit/sec)
Vendor OUI Of Transceiver: 00:17:6a
Wavelength In Nanometers: 850
Date Code Of Transceiver: 15:10:26
Validity Of Transceiver: true
Connector Used: LC
Encoding Used: 64B66B
Is Internally Calibrated: true
Received Optical Power: 56.2 (uWatts)
Is Received Power In Range: true
SPF Transmitted Optical Power: 610.0 (uWatts)
Is Xmit Power In Range: true