跳转到主内容

LIF 不适用于板载 CNA 网络接口

Views:
31
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

适用场景

  • ONTAP 9
  • QLogic CNA8324端口

问题描述

  • SnapMirror传输 可能会失败 、并显示错误、如所述 snapmirror show -fields state, status, health, last-transfer-error

Error: command failed: Failed to get information for source volume "volume_node_name:volume_name" for confirmation. (CSM: A get-session operation failed because no (local) transport address was registered for the node.)

  • EMS会记录过渡到非活动状态的端口。示例

[node-name: intr: net.ifgrp.lacp.link.inactive:error]: ifgrp a0a, port e0g has transitioned to an inactive state. The interface group is in a degraded state.
[node_name: intr: net.ifgrp.lacp.link.inactive:error]: ifgrp a0a, port e0e has transitioned to an inactive state. The interface group is in a degraded state.

  • 如果受影响的端口上存在集群间生命周期、 cluster peer ping 则无法访问。
  • LIF运行状态为"已关闭"。示例:

::> network interface show -role intercluster
       Logical   Status    Network       Current     Current Is
Vserver    Interface  Admin/Oper Address/Mask     Node      Port   Home
----------- ---------- ---------- ------------------ ------------- ------- ----
VServer
      [...]
      lif-intc   up/down   x.x.x.x/x      node-name    a0a-11 true

  • ifconfig -vvv 输出中未收到但发送LACPDU。示例

a0a: flags=8888<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 9000
   ...
   laggport: e0g flags=22222<DEFAULT> state=45<ACTIVITY,AGGREGATION,DEFAULTED>
      ...
       input/output LACPDUs: 0 / 123456

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.