LED1 或 LED2 传感器达到非关键阈值上限,导致环境停机
适用于
- AFF A400,AFF C400
- ASA A400、ASA C400、
- FAS8300、FAS8700
- AFF A800,AFF C800
- ASA A800、ASA C800
- ONTAP 9
问题描述
- 温度传感器 LED1 和 LED2 在达到非临界阈值上限(43°C)时会触发环境停机,而不是通常触发环境停机的临界阈值上限:
[Node1: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is warning high. System will be shutdown in 2 minutes
[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: LED2 Temp is warning high (43 C).
[Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high..
[Node1: env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
[Node1: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
- HA 对中的两个节点均已关闭,导致服务中断。