由于内部通信问题,将节点加入集群失败
- Views:
- 11
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-9
- Specialty:
- core<a>20089563774</a><a>进行翻译</a>
- Last Updated:
适用场景
- ONTAP 9
- FAS/AFF
问题描述
- 将新节点加入现有集群失败,并显示以下内容:
Joining cluster ..............Error: Cluster applications failed to initialize due to internal communication problems. Run the setup wizard again to resolve the problem. Contact support personnel if the problem persists.
- System Manager 将显示以下警报:
Probable Cause: MTU value "4294967295" on port "e0a" of node
"NODE12" is improperly set. It should be 9000.
Possible Effect: Received Ethernet packets that are larger than the
configured MTU are dropped, causing data transfer issues.
Corrective Actions: modify the MTU using the command "network port
broadcast-domain modify -ipspace Cluster -broadcast-domain Cluster -mtu
".
To find out the broadcast domain name of the port, execute the command
"network port broadcast-domain show".