更换主板后 SP 固件是否自动更新

Views:
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • SP 固件更新

回答

  • 自动更新机制取决于是否启用了自动更新选项。
  • 当更换主板的 BMC 固件版本低于原始版本时,ONTAP 尝试 SP/BMC 固件自动更新最多三次;如果所有尝试都失败,则不再进行重试,需要手动更新。
  • 如果更换的主板具有较新的固件版本,ONTAP 不会执行降级。在这种情况下,应更新配对节点以匹配相同的 SP 固件版本。

追加信息

追加信息_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.