跳转到主内容

监控 ds.sas.drivephy.disableErr 是否足以检测磁盘缺失事件

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9.12.1
  • FAS8300

回答

  • ds.sas.drivephy.disableErr 消息不是磁盘缺失事件的初始指示器。
  • 此日志在磁盘已无响应或丢失一段时间后生成。
  • 由于磁盘无响应导致过多错误,控制器禁用相关的 PHY。因此,此消息是磁盘丢失的结果,而不是最早的警报。
  • 使用 Autosupport 通知监控 FILESYSTEM DISK NOT RESPONDING 磁盘缺失事件
    示例:
    Callhome for FILESYSTEM DISK NOT RESPONDING
    ASUP notifications can automatically open support cases for hardware issues, providing timely visibility.

追加信息

追加信息_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.