仅从一个节点 AFF A250 看到内部磁盘
适用于
- AFF A250
- AFF C250
- 内部磁盘
问题描述
- 从 HA 对中的一个节点看不到驱动器。示例:
节点 A
slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
11 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
节点 B:
slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
{Disk 00.11 expected here , but missing}
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
- 错误消息示例:
[Node_name: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0n.11 Shelf 0 Bay 11 [NETAPP X4013S17337T6NTE NA53] S/N [xxxxxxxxx] UID [...] is missing.