跳转到主内容

仅从一个节点AFF A250中检测到内部磁盘

Views:
3
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • AFF A250
  • AFF C250
  • 内部磁盘

问题描述

  • 更换磁盘后、 HA对中的一个节点上看不到驱动器。示例

节点 A

slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
11 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)

节点B:

slot 0: Virtual NVMe Host Adapter 0n
10 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)
{Disk 00.11 expected here , but missing}
12 : NETAPP X4013S17337T6NTE NA53 7325.4GB 4160B/sect (xxxxxxxxx)

  • 错误消息。示例

[Node_name: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0n.11 Shelf 0 Bay 11 [NETAPP   X4013S17337T6NTE NA53] S/N [xxxxxxxxx] UID [...] is missing.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.