对于 NS224 磁盘架, NSM100 模块中的 Coin 电池出现间歇性警告
- Views:
- 9
- Visibility:
- Public
- Votes:
- 0
- Category:
- disk-shelves<a>磁盘架</a><a>NS224</a><a>NSM100</a><a>2008657872</a><a>用于</a><a>转换</a><a>的一枚硬币电池</a>
- Specialty:
- hw
- Last Updated:
适用场景
- NS224 架
- 0141 磁盘架固件
问题描述
- NS224 磁盘架模块 NSM100 报告:
Wed Feb 03 18:50:42 +0100 [node_name: dsa_worker3: ses.status.battery.threshErr:alert]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: critical status. This element is on the rear of the shelf, in top module (A).
Wed Feb 03 19:16:54 +0100 [node_name: dsa_worker3: ses.status.battery.info:notice]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery information for Coin Battery 1: normal status.
- 重新拔插模块后、此情况无法清除
- 更换电池后、此情况不会清除
- AutoSupport 中的其他指示:
- 如果在触发Autossupport之前更正了故障条件、则无法找到此故障的进一步证据。
- 如果在之间触发了AutoSupport
battery failure error for Coin Battery 1: critical status
、battery information for Coin Battery 1: normal status
并且在存储故障和环境输出中注册了问题描述 :
- 存储故障输出
Coin Cell Battery:
Element Status Status Bytes Status Descriptions
1 [NSM100 A] : CRITICAL 02,02,0A,46 LCR
2 [NSM100 B] : OK 01,00,0B,34
- Coin电池的环境输出:
Coin Battery installed element list: 1, 2; with error: 1
Coin Battery information by element:
[1] Voltage: 2.630
[2] Voltage: 2.868