跳转到主内容

Fabric MetroCluster のInterconnectAdapterOfflineAlert

Views:
9
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster<a>2009473824</a>
Last Updated:

環境

  • ONTAP 9
  • FAS / AFFシステム
  • ファブリック接続MetroCluster

問題

  • イベントログで確認されるアラートは次のとおりです。

[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = InterconnectAdapterOfflineAlert , Alerting Resource = 2100fXXXXXXXXX777 raised by monitor node-connect

  • FCVIポートのステータスがdownと表示されます。

slot 1: FCVI Host Adapter 1b (QLogic 8324(2672) rev. 2, unknown)
       Physical link:     DOWN
       FC Node Name:     21:00:f4:e9:d4:eb:b7:77
       Firmware rev:     8.01.141
       Serial No:       UFE12345678
       Host Port Id:     0xffffffff
       FC Packet size:    2048
       Reading SFP information failed

  • ポートが  スイッチログからCRCエラーを報告する場合があります。

porterrshow:
   frames    enc  crc  crc   too  too  bad   enc   disc  link   loss   loss   frjt   fbsy  c3timeout  pcs  uncor
   tx   rx   in  err  g_eof  shrt  long  eof   out   c3   fail   sync   sig          tx   rx  err   err
3: 427.7k 333.2k  0  5.1k 5.1k  0    0   82    0   893    4    1    1    0    0   889  0    0   0 

  • スイッチ側のSFPが 低受信電力を報告しています。

Switch> sfpshow 3

Port 3:
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
Vendor Name: BROCADE
Temperature: 40 Centigrade
Current: 8.220 mAmps
Voltage: 3340.3 mVolts
RX Power: -15.7 dBm (26.8 uW) ---> low receive end power detected
TX Power: -2.6 dBm (546.0 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.