跳转到主内容

检测到连接到适配器的磁盘架配置不一致

Views:
39
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>2009608141.</a>
Specialty:
HW
Last Updated:

适用场景

  • FAS2620
  • FAS2240
  • DS2246
  • DS424x

问题描述

  • 磁盘架故障会在 EMS日志中报告:
6/13/2023 13:00:00  Node-01 ERROR     monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
6/13/2023 13:00:00  Node-02 ERROR     monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
6/13/2023 12:57:19  Node-01 ALERT     ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
6/13/2023 12:56:53  Node-02 ALERT     ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
  • IOM模块 NONCRITICAL 位于ASUP中 STORAGE-FAULT 
Vendor Unique Element 83-IOM6: (SAS)
Element Status      Status Bytes  Status Descriptions
  1 [IOM6 A]   : NONCRITICAL     03,09,00,20   SHELF ID DELTA, MASTER, RESERVED
  2 [IOM6 B]   : NONCRITICAL     03,01,00,20   SHELF ID DELTA, RESERVED
  • SAS磁盘架ID自发更改
::*> run -node Node-01 -command sasadmin expander_cli 0b.1 "set_encl_id"
Node: Node-01
Current Enclosure ID: 1
Pending Enclosure ID: 94
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.