检测到连接到适配器的磁盘架配置不一致
适用场景
- FAS2620
- FAS2240
- DS2246
- DS424x
问题描述
- 磁盘架故障会在 EMS日志中报告:
6/13/2023 13:00:00 Node-01 ERROR monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
6/13/2023 13:00:00 Node-02 ERROR monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
6/13/2023 12:57:19 Node-01 ALERT ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
6/13/2023 12:56:53 Node-02 ALERT ses.inconsistent.config: Inconsistent configuration detected for shelf connected to adapter 0b.
- IOM模块
NONCRITICAL
位于ASUP中STORAGE-FAULT
Vendor Unique Element 83-IOM6: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM6 A] : NONCRITICAL 03,09,00,20 SHELF ID DELTA, MASTER, RESERVED
2 [IOM6 B] : NONCRITICAL 03,01,00,20 SHELF ID DELTA, RESERVED
- SAS磁盘架ID自发更改
::*> run -node Node-01 -command sasadmin expander_cli 0b.1 "set_encl_id"
Node: Node-01
Current Enclosure ID: 1
Pending Enclosure ID: 94