跳转到主内容

如何识别IOM12与IOM12B之间的区别?

Views:
97
Visibility:
Public
Votes:
1
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • DS224C、DS212C、DS460C SAS3 存储架
  • IOM12、IOM12B 架模块

问题解答

  • 视觉识别:
    • 模块上的标签显示“IOM12”或“IOM12B”,
    • IOM12模块没有蓝色条纹。IOM12B 模块的面板上有一条蓝色条纹。

IOM12和IOM12B之间的区别

  • 查看storage shelf show -module 或(nokeshell) environment status shelf 命令行界面命令的输出:
    • IOM12报告以下Mfg.3x5部件号:111-02850
    • IOM12B报告以下Mfg.3x5部件号:111-04850或111-05055
  • 查看system controller config show 或(nokeshell) sysconfig -a 命令行界面命令的输出:
    • 磁盘架信息将报告IOM型号(IOM12或IOM12B)
 Shelf 10: DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120 

 

 

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.