运行状况警报显示 " 存储架未连接到 HA 对的两个控制器 "
适用场景
- ONTAP 9
- DS460C
问题描述
- 运行状况更改器显示 "" 。
Storage shelf is not connected to both controllers of the HA pair
Cluster::> system health alert show
Node: node A
Resource: Shelf 8.12
Severity: Major
Indication Time: Wed Jun 10 16:46:33 2020
Suppress: false
Acknowledge: false
Probable Cause: Storage shelf 8.12 is not connected to both
controllers of the HA pair (node A, node B).
Possible Effect: Access to shelf 8.12 will be lost with a single
controller failure.
Corrective Actions: 1. Halt all controllers that are connected to shelf 8.12.
2. Connect shelf 8.12 to both HA controllers following the guide applicable to your shelf.
3. Reboot the halted controllers.
- 中显示了 IOM
FAIL
storage show fault
:
Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,40,00,00 FAIL
2 [IOM12 A] : OK 01,00,01,00 REPORT
3 [IOM12 A] : OK 01,00,01,00 REPORT
4 [IOM12 A] : OK 01,00,01,00 REPORT
5 [IOM12 A] : OK 01,00,01,00 REPORT
6 [IOM12 B] : OK 01,00,01,00 REPORT
7 [IOM12 B] : OK 01,00,01,00 REPORT
8 [IOM12 B] : OK 01,00,01,00 REPORT
9 [IOM12 B] : OK 01,00,01,00 REPORT
10 [IOM12 B] : OK 01,00,01,00 REPORT