core<a>SNMP</a><a>CSHM</a><a>2008284963</a><a>SwitchCommunityString_Alert 警报</a>
Last Updated:

适用场景

  • NetApp CN1610 集群网络交换机( CNS )
  • Cisco集群交换机
  • ONTAP 9
  • CSHM (集群交换机运行状况监控器)

问题描述

  • HA Group Notification from xxxxxx  (Health Monitor process cshm: SwitchCommunityString_Alert[xxxxxxxx]) ALERT系统会按随机间隔发送。
  • 系统运行状况警报show rePOTS

Node: NodeA
Monitor: cluster-switch
Alert ID: SwitchCommunityString_Alert
Alerting Resource: Switch_A
Subsystem: Switch-Health
Indication Time: Thu May 18 06:09:58 2023
Perceived Severity: Major
Probable Cause: Configuration_error
Description: Cluster switch "Switch_A" with IP address "xxx.xxx.xxx.xxx" is not reachable via SNMP. Incorrect SNMP community string might be configured on the cluster switch.
Corrective Actions: Check the SNMP community string on the cluster switch to verify the expected community string is configured. Use the "system cluster-switch show -snmp-config" command to view the expected community string.
Possible Effect: Cluster switch communication problems and accessibility issues.
Acknowledge: false
Suppress: false
Policy: SwitchCommunityString_Policy
Acknowledger: -
Suppressor: -
Additional Information: Switch Name:Switch_A
Switch Model:NX3232C
Alerting Resource Name: Switch_A
Additional Alert Tags: -

  • CSHmd 和 MGWD 消息示例:

Sun Aug 29 01:53:47 +0100 [node_name: cshmd: hm.alert.raised:alert]: Alert Id = SwitchCommunityString_Alert , Alerting Resource = switch_name1 raised by monitor cluster-switch
Sun Aug 29 01:53:47 +0100 [node_name: cshmd: hm.alert.raised:alert]: Alert Id = SwitchCommunityString_Alert , Alerting Resource = switch_name2 raised by monitor cluster-switch
Sun Aug 29 01:57:38 +0100 [node_name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchCommunityString_Alert[switch_name1].

  • 无法访问集群网络交换机

Cluster switch "MANMCSCLSSW001" with IP address "switch2_mgmt_IP"is not reachable via SNMP. Incorrect SNMP community string might be configured on the cluster switch.
Cluster switch "MANMCSCLSSW002" with IP address "switch2_mgmt_IP"is not reachable via SNMP. Incorrect SNMP community string might be configured on the cluster switch.

  • 集群交换机配置示例:

Device Name           switch_name1         switch_name2
IP Address           123.123.123.123        123.123.123.124
Model to display        CN1610            CN1610
Switch Network         cluster-network        cluster-network
Software Version        1.3.0.2            1.3.0.2
SNMP Version          SNMPv2c            SNMPv2c
Is Discovered          true             true
Switch Monitoring Status    false             false
Reason For Not Monitoring   IP address not reachable   IP address not reachable
Serial Number of the Device   Unknown            Unknown

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.