在 FAS8200 和 AFF A300 平台上处理二级看门狗复位
适用于
- AFF A300
- FAS8200
问题描述
- 节点意外重新启动。
- 或者节点在意外关闭后不会重新启动。
- 受影响节点上的服务处理器日志显示以下内容:
Record 454: Mon Feb 08 11:49:20.924775 2021 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 455: Mon Feb 08 11:49:20.984259 2021 [Trap Event.critical]: hwassist l2_watchdog_reset (29)
Record 456: Mon Feb 08 11:49:23.000822 2021 [SP.critical]: Filer Reboot
- 如果节点重新启动,可以在 EMS 日志文件中看到以下错误:
[cluster-01:mgr.boot.reason_abnormal:EMERGENCY]: System rebooted due to a watchdog reset.
- 如果节点无法重新启动,
system sensorsSP 可能会显示传感器不可用(na)或故障(Fault):
Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
SYSTEM:
System_FW_Status | na | discrete | na | na | na | na | na
System_Watchdog | 0x0 | discrete | | na | na | na | na
Wrench_Port_Up | na | discrete | na | na | na | na | na
CONTROLLER_A:
PCM_Status | 0x0 | discrete | Fault | na | na | na | na
Attn_Sensor1 | 0x0 | discrete | Asserted | na | na | na | na
CPU-1_DTS_Temp | na | degrees C | na | na | na | -10.000 | 0.000
CPU-2_DTS_Temp | na | degrees C | na | na | na | -10.000 | 0.000
CPU0_PVCCP | na | Volts | na | 1.580 | 1.670 | 1.920 | 2.010
CPU1_PVCCP | na | Volts | na | 1.580 | 1.670 | 1.920 | 2.010