跳转到主内容

在 FAS8200 和 AFF A300 平台上处理二级看门狗复位

Views:
110
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用于

  • AFF A300
  • FAS8200

问题描述

  • 节点意外重新启动。
  • 或者节点在意外关闭后不会重新启动。
  • 受影响节点上的服务处理器日志显示以下内容: 

Record 454: Mon Feb 08 11:49:20.924775 2021 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 455: Mon Feb 08 11:49:20.984259 2021 [Trap Event.critical]: hwassist l2_watchdog_reset (29)
Record 456: Mon Feb 08 11:49:23.000822 2021 [SP.critical]: Filer Reboot

  • 如果节点重新启动,可以在 EMS 日志文件中看到以下错误:

[cluster-01:mgr.boot.reason_abnormal:EMERGENCY]: System rebooted due to a watchdog reset.

  • 如果节点无法重新启动,system sensors SP 可能会显示传感器不可用(na)或故障(Fault):

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
SYSTEM:
System_FW_Status | na      | discrete   | na      | na     | na     | na     | na
System_Watchdog  | 0x0     | discrete   |       | na     | na     | na     | na
Wrench_Port_Up   | na      | discrete   | na      | na     | na     | na     | na
CONTROLLER_A:
PCM_Status     | 0x0     | discrete   | Fault    | na     | na     | na     | na
Attn_Sensor1    | 0x0     | discrete   | Asserted   | na     | na     | na     | na
CPU-1_DTS_Temp   | na      | degrees C  | na      | na     | na     | -10.000   | 0.000
CPU-2_DTS_Temp   | na      | degrees C  | na      | na     | na     | -10.000   | 0.000
CPU0_PVCCP     | na      | Volts    | na      | 1.580    | 1.670    | 1.920    | 2.010
CPU1_PVCCP     | na      | Volts    | na      | 1.580    | 1.670    | 1.920    | 2.010

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.