跳转到主内容

host_port_fail—由于SAS缆线故障、IOM警报已禁用

Views:
26
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009414015</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFA
  • 磁盘架

问题描述

  • 以下事件将在EMS日志中报告:

[node-02: dsa_worker0: ds.sas.running.disparity:debug]: [HST2/P0:2] on channels 0b shelf ID 1 IOM B bay - reports running disparity errors.
[node-02: dsa_worker2: ds.sas.hostphy.disableErr:alert]: Port [HST2/P0:3] on channels 0b shelf ID 1 IOM B disabled due to excessive invalid dword error.
[node-02: dsa_worker2: callhome.hostport.disable:alert]: Call home for HOST_PORT_FAIL - Disabled by IOM

  • STORAGE-SHELF 第节可以看出、由于错误过多、受影响的PHY已禁用: 

Shelf name:   0a.shelf1
Shelf id:    1
Channel:     0a
Module:     B
Shelf UID:    50:0a:09:80:07:fa:d6:80
Shelf S/N:    SHJSXXXXXXXXXXX
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

                     Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk          Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id           State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------------
[HST0/P0:0 ] OK             7       12.0        0           0       0        0         0       3
[HST1/P0:1 ] OK             7       12.0        0           0       0        0         0       3
[HST2/P0:2 ] DIS/INVWD     7         NA     3496     2806      0        0         0       4
[HST3/P0:3 ] DIS/INVWD   7      NA   6598     3415     0     0      0    20

  • 受影响的SAS端口 将PHY报告为未知或已禁用:

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
       Firmware rev:     03.08.09.00
       Base WWN:       5:00a098:003cf2e:30
       Temperature:     Not Available
       Phy State:      [0] Enabled, 12.0 Gb/s
                 [1] Enabled, 12.0 Gb/s
                 [2] Enabled, Rate unknown
                 [3] Disabled

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.