跳转到主内容

AFF-A900 上频繁出现 CHASSIS OVER TEMPERATURE 警报

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

•    AFF-A900 
•    网络接口卡 (NIC) X91152A
•    QSFP X6589-R6 

问题

  • EMS 日志经常触发 Call Home for CHASSIS OVER TEMPERATURE 警报。

    Tue Mar 31 13:21:31 +0900 [node-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
  • 插槽 3 卡上的 e3d 端口及其关联的 VLAN 端口在链路连接和链路关闭状态之间反复循环:

    • 链接启动事件:
      Wed Apr 01 09:57:11 +0900 [node-01: kernel: netif.linkUp:info]: Ethernet e3d: Link up. Wed Apr 01 09:57:11 +0900 [node-01: intr: netif.linkUp:info]: Ethernet e3d-641: Link up.
    • 链接关闭事件:
      Wed Apr 01 09:57:18 +0900 [node-01: kernel: netif.linkDown:info]: Ethernet e3d: Link down, check cable. Wed Apr 01 09:57:18 +0900 [node-01: intr: netif.linkDown:info]: Ethernet e3d-641: Link down, check cable.
    • 未分配给任何广播域的端口:
      Wed Apr 01 09:57:39 +0900 [node-01: vifmgr: vifmgr.reach.unassn:notice]: Network port e3d on node node-01 is not assigned to any broadcast domain. No broadcast domains appear to be reachable from this port. Wed Apr 01 09:57:39 +0900 [node-01: vifmgr: vifmgr.reach.skipped:notice]: Network port e3d on node node-01 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
  • EMS 日志经常显示 chassisTemperature.warm 警报:

    Wed Apr 01 09:58:06 +0900 [node-01: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Port temps at max and fans at max speed
  • PLATFORM-SENSORS 中, MLX Highest Temp  的传感器值偶尔显示状态为  crit-high

    • 传感器输出示例:
      MLX Highest Temp thermal crit-high 85 C 65

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.