AFF-A900 上频繁出现 CHASSIS OVER TEMPERATURE 警报
适用于
• AFF-A900
• 网络接口卡 (NIC) X91152A
• QSFP X6589-R6
问题
EMS 日志经常触发 Call Home for
CHASSIS OVER TEMPERATURE警报。Tue Mar 31 13:21:31 +0900 [node-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE插槽 3 卡上的
e3d端口及其关联的 VLAN 端口在链路连接和链路关闭状态之间反复循环:- 链接启动事件:
Wed Apr 01 09:57:11 +0900 [node-01: kernel: netif.linkUp:info]: Ethernet e3d: Link up. Wed Apr 01 09:57:11 +0900 [node-01: intr: netif.linkUp:info]: Ethernet e3d-641: Link up. - 链接关闭事件:
Wed Apr 01 09:57:18 +0900 [node-01: kernel: netif.linkDown:info]: Ethernet e3d: Link down, check cable. Wed Apr 01 09:57:18 +0900 [node-01: intr: netif.linkDown:info]: Ethernet e3d-641: Link down, check cable. - 未分配给任何广播域的端口:
Wed Apr 01 09:57:39 +0900 [node-01: vifmgr: vifmgr.reach.unassn:notice]: Network port e3d on node node-01 is not assigned to any broadcast domain. No broadcast domains appear to be reachable from this port. Wed Apr 01 09:57:39 +0900 [node-01: vifmgr: vifmgr.reach.skipped:notice]: Network port e3d on node node-01 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
- 链接启动事件:
EMS 日志经常显示
chassisTemperature.warm警报:Wed Apr 01 09:58:06 +0900 [node-01: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Port temps at max and fans at max speed在
PLATFORM-SENSORS中,MLX Highest Temp的传感器值偶尔显示状态为crit-high。- 传感器输出示例:
MLX Highest Temp thermal crit-high 85 C 65
- 传感器输出示例: