适用场景
- ONTAP
- E 系列
问题描述
在维护接管期间、由LUN托管的E系列阵列组成的RAID 0 FlexArray 聚合出现故障
事件日志示例:
第一个节点
[Node_1: sanown_io: diskown.changingOwner:info]: Changing ownership of disk switch_1:1-24.126L92 (S/N 123) from node "Node_1" (ID 1, DR home ID) to node "Node_2" (ID, DR home ID).
[Node_1: hamsg: disk.partner.diskFail:debug]: The partner with sysid xyz has failed switch_1:1-24.126L92.
第二个节点
[Node_2: config_thread: raid.assim.disk.brokenPreAssim:error]: Broken Disk switch_2:1-24.126L92 Shelf - Bay - [NETAPP INF-01-00 0872] S/N [123] UID [] detected prior to assimilation.