跳转到主内容

由于Flash Cache出现故障、Flash Cache脱机

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

ONTAP 9

问题描述

  • 的故障LED亮起SP-LATEST-RUNTIME

========
FRU LEDs status
======================
<snip>
FRU LED ID 14 = BMC DIMM Slot 2 Attention LED
FRU LED ID 15 = BMC NVMEM 1 Attention LED
FRU LED ID 16 = BMC BOOT DISK Attention LED
<snip>
FRU LED ID 14 is off
FRU LED ID 15 is on 
FRU LED ID 16 is off

  • 错误事件是从SP-LATEST-IPMI 报告的。

 Node        ID  Event Location            Event Description
 ---------------- --- ----------------------------------  ----------------------
      node-01  1 Device in M.2 PCIe slot 1 in Controller A  NVMe device failed

  • EMS 显示Flash Cache脱机。

Mon May 12 19:17:16 +0100 [Node Name: node01: callhome.nvme.exhausted:alert]: Callhome for Flash Cache NVMe Offline.

  • SYSCONFIG -A 显示Flash Cache失败。

slot 1: Flash Cache NVMe
Part Number: 119-00329
Hardware Revision: A0
Firmware Version: NA03
Model Name: X3311A
Capacity: 1024 GB
State: failed

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.