跳转到主内容

文件系统磁盘丢失后磁盘初始化失败

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • 因文件系统磁盘丢失而呼叫总部
  • 固态硬盘(SSD)

问题描述

文件系统磁盘缺失,随后出现磁盘初始化失败和磁盘读取保留失败
 
Node2
Mon Sep 15 16:18:55 [node2: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 5a.10.18: Adapter/target error: HA status 0x7: cdb 0x2f:e7276c00:0400. Targeted device did not respond to requested I/O. I/O will be retried. Disk 5a.10.18 Shelf 10 Bay 18 [NETAPP X319_SLBPE7T6ATE NA51] S/N [xxxxxxxx] UID [5000C500:EC891FDF:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
Mon Sep 15 16:18:55 [node2: scsi_cmdblk_strthr_admin: scsi.cmd.noMorePaths:error]: Disk device 5a.10.18: No more paths to device: cdb 0x2f:e7276c00:0400. All retries have failed.
Mon Sep 15 16:18:55 [node2: scsi_cmdblk_strthr_admin: scsi.cmd.noMorePaths:error]: Disk device 5a.10.18: No more paths to device: cdb 0x2f:e7276800:0400. All retries have failed.
Mon Sep 15 16:18:55 [node2: sanown_io: diskown.errorDuringIO:error]: error 25 (no valid path to disk) on disk 5a.10.18 (S/N xxxxxxxx) while setting disk reservation
Mon Sep 15 16:18:55 [node2: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1/plex0/rg0/5d.10.18 Shelf 10 Bay 18 [NETAPP X319_SLBPE7T6ATE NA51] S/N [xxxxxxxx] UID [5000C500:EC891FDF:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Mon Sep 15 16:18:55 [node2: scsi_cmdblk_strthr_admin: disk.reserveFailed:error]: Disk reservation failed on 5a.10.18 CDB 0x5e:01 - SCSI:no sense (0 0 0)
Mon Sep 15 16:18:55 [node2: config_thread: raid.rg.recons.missing:notice]: RAID group /aggr1/plex0/rg0 is missing 1 disk(s).
Mon Sep 15 16:19:35 [node2: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING
 
Mon Sep 15 16:38:11 [node2: scsi_cmdblk_strthr_admin: disk.init.failure.error:error]: Drive 5a.10.18 failed initialization due to error 5, sense code(4 31 0 18).
Mon Sep 15 16:38:11 [node2: scsi_cmdblk_strthr_admin: disk.readReservationFailed:error]: Disk read reservation failed on 5a.10.18 CDB 0x5e:01 - SCSI:hardware error (4 31 0)
Mon Sep 15 16:38:11 [node2: sanown_io: diskown.errorDuringIO:error]: error 13 (fatal disk error) on disk 5a.10.18 (S/N ) while reading reservation state
Mon Sep 15 16:38:11 [node2: rastrace_dump: rastrace.dump.saved:debug]: A RAS trace dump for module RAID instance 0 was stored in /etc/log/rastrace/RAID_0_20250915_16:38:11:284531.dmp.
Mon Sep 15 16:38:57 [node2: scsi_cmdblk_strthr_admin: disk.releaseFailed:error]: Disk release failed on 5d.10.18 CDB 0x5f:0601 - SCSI:hardware error (4 31 0)
 
Node1
Mon Sep 15 16:38:10 [node1: scsi_cmdblk_strthr_admin: disk.init.failure.error:error]: Drive 5a.10.18 failed initialization due to error 5, sense code(4 31 0 18).
Mon Sep 15 16:38:10 [node1: scsi_cmdblk_strthr_admin: disk.readReservationFailed:error]: Disk read reservation failed on 5a.10.18 CDB 0x5e:01 - SCSI:hardware error (4 31 0)
Mon Sep 15 16:38:10 [node1: sanown_io: diskown.errorDuringIO:error]: error 13 (fatal disk error) on disk 5a.10.18 (S/N ) while reading reservation state
Mon Sep 15 16:38:10 [node1: rastrace_dump: rastrace.dump.saved:debug]: A RAS trace dump for module RAID instance 0 was stored in /etc/log/rastrace/RAID_0_20250915_16:38:10:872376.dmp.
Mon Sep 15 16:38:37 [node1: scsi_cmdblk_strthr_admin: disk.releaseFailed:error]: Disk release failed on 5d.10.18 CDB 0x5f:0601 - SCSI:hardware error (4 31 0)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.