适用场景

FAS2650

问题描述

  • 节点关闭、配对节点报告正在执行接管
CLTFLT:HA Group Notification from Node-01 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC) ALERT
  • 显示多个故障磁盘
cluster::> storage disk show -broken
Original Owner: Checksum Compatibility: block
Drawer Usable Physical Disk Outage Reason
HA Shelf Bay /Slot Chan Pool Type RPM Size Size
--------------- ------------- --- ----- --- ------ ----
4.2.4     failed 0a 2 4 -/- B NONE SAS 10000 - 1.64TB
4.2.12    failed 0a 2 12 -/- B NONE SAS 10000 - 1.64TB
4.2.16    failed 0a 2 16 -/- B NONE SAS 10000 - 1.64TB
4.3.4     failed 0b 3 4 -/- A NONE SAS 10000 - 1.64TB
4.3.6     failed 0b 3 6 -/- A NONE SAS 10000 - 1.64TB
4.3.20    failed 0b 3 20 -/- A NONE SAS 10000 - 1.64TB
 
cluster::> node run -node Node-02 sysconfig -r
Aggregate aggr2_cluster_02_SAS (failed, mixed_raid_type, partial, hybrid) (block checksums)
  Plex /aggr2_cluster_02_SAS/plex0 (offline, failed, inactive)
    RAID group /aggr2_cluster_02_SAS/plex0/rg0 (partial, block checksums, raid_dp)
      RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
      dparity    0a.02.0    0a    2   0   SA:A   0   SAS 10000 1713523/3509295616 1716957/3516328368
      parity     0b.03.0    0b    3   0   SA:B   0   SAS 10000 1713523/3509295616 1716957/3516328368
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      data   FAILED        N/A                        1713523/ -
      Raid group is missing 8 disks.
  • 聚合显示为故障/脱机
  • SCSI cmd checkconditions 在磁盘出现故障之前显示在EMS日志中
[Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0b.03.10: Check Condition: CDB 0x2a:a7fc9600:0200: Sense Data SCSI:hardware error -  (0x4 - 0x3 0x0 0x82)(994).
[Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.02.6: Check Condition: CDB 0x2a:a7fc9600:0200: Sense Data SCSI:hardware error -  (0x4 - 0x3 0x0 0x8)(1480).
[Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.02.8: Check Condition: CDB 0x2a:a7fc9600:0200: Sense Data SCSI:hardware error -  (0x4 - 0x3 0x0 0x8)(1512).
[Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.02.10: Check Condition: CDB 0x2a:a7fc9600:0200: Sense Data SCSI:hardware error -  (0x4 - 0x3 0x0 0x8)(1525).
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.