AFF A400、FAS8300、FAS4700因多个机箱风扇出现故障而关闭:系统将在2分钟内关闭

Views:
13
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009年27月367日</a>
Last Updated:

适用场景

  • FAS8300
  • FAS8700
  • AFF A400

问题描述

  • 节点重新启动并显示以下警报:

HA Group Notification (MULTIPLE CHASSIS FAN FAILED: System will shut down in 2 minutes) ERROR

  • 事件日志中会显示以下错误:

[Node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Fan4_1 (failed)
[Node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Fan4_2 (failed)
[Node-02: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[Node-02: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: SysFan4 F2, SysFan4 F1. 
[Node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan4_1
[Node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan4_2

  • 在 SP-LATEST-IPMI AutoSupport部分中未看到受影响风扇模块的传感器读数:

Fan1_1       | 70h | ok  | 29.1 | 12600 RPM
Fan2_1       | 71h | ok  | 29.2 | 12600 RPM
Fan3_1       | 72h | ok  | 29.3 | 12600 RPM
Fan4_1      | 73h | ns  | 29.4 | No Reading
Fan1_2       | 74h | ok  | 29.1 | 12600 RPM
Fan2_2       | 75h | ok  | 29.2 | 12600 RPM
Fan3_2       | 76h | ok  | 29.3 | 12600 RPM
Fan4_2      | 77h | ns  | 29.4 | No Reading

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 