AFF A400、FAS8300、FAS4700因多个机箱风扇出现故障而关闭:系统将在2分钟内关闭
适用场景
- FAS8300
- FAS8700
- AFF A400
问题描述
- 节点重新启动并显示以下警报:
HA Group Notification (MULTIPLE CHASSIS FAN FAILED: System will shut down in 2 minutes) ERROR
- 事件日志中会显示以下错误:
[Node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Fan4_1 (failed)
[Node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Fan4_2 (failed)
[Node-02: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[Node-02: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: SysFan4 F2, SysFan4 F1.
[Node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan4_1
[Node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan4_2
- 在
SP-LATEST-IPMI
AutoSupport部分中未看到受影响风扇模块的传感器读数:
Fan1_1 | 70h | ok | 29.1 | 12600 RPM
Fan2_1 | 71h | ok | 29.2 | 12600 RPM
Fan3_1 | 72h | ok | 29.3 | 12600 RPM
Fan4_1 | 73h | ns | 29.4 | No Reading
Fan1_2 | 74h | ok | 29.1 | 12600 RPM
Fan2_2 | 75h | ok | 29.2 | 12600 RPM
Fan3_2 | 76h | ok | 29.3 | 12600 RPM
Fan4_2 | 77h | ns | 29.4 | No Reading