错误警报存储架未连接到的两个控制器 HA 对
适用场景
- ONTAP 9.5 及更低版本
- 所述节点已正确连接到磁盘架,无需任何问题描述即可访问
- 在警报计时期间未执行任何其他活动
问题描述
- 集群触发警报:
::> alert show
(system health alert show)
Node: node_name_03
Resource: Shelf 3.0
Severity: Major
Indication Time: Fri Oct 16 17:01:21 2020
Suppress: false
Acknowledge: false
Probable Cause: Storage shelf 3.0 is not connected to both controllers
of the HA pair (node_name-01, node_name-02).
Possible Effect: Access to shelf 3.0 will be lost with a single
controller failure.
Corrective Actions: 1. Halt all controllers that are connected to shelf 3.0.
2. Connect shelf 3.0 to both HA controllers following the guide applicable to your shelf.
3. Reboot the halted controllers.- 集群将触发以下警报:
HA Group Notification from XXXXXX(Health Monitor process schm: DualControllerHa_Alert[XXXXXX]) ALERT - 可以从 EMS 日志确认以下输出。
[?] Sun Oct 11 00:00:44 JST [XXXXXX: spmd: spm.mgwd.process.exit:EMERGENCY]: Management Gateway (mgwd) subsystem with ID 87957 exited as a result of signal signal 11. The subsystem will attempt to restart.
~
[?] Sun Oct 11 00:11:36 JST [XXXXXX: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: DualControllerHa_Alert[XXXXXX].