问题

  • 事件日志条目指示 FC 链路已断开连接:

5/23/2020 21:11:31  cluster-node1  ERROR scsitarget.ispfct.linkBreak: Link break detected on Fibre Channel target adapter 1b. Firmware status code status1 0x2, status2 0x7, and status4 0x0.

  • sysconfg -a 将端口状态报告为“Link Disconnected”

slot 1: Fibre Channel Target Host Adapter 1b
                (QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
                Board Name:        QLE2672
                Serial Number:     RFE2005W04482
                Firmware rev:      8.9.0
                Flash rev:         1.1.2
                Host Port Addr:    000000
                FC Nodename:       xx:0a:09:80:80:xx:xy:xx (500a098080b3a125)
                FC Portname:       xx:0a:09:82:80:xy:yy:xx (500a098280b3a125)
                Connection:        No link
                Switch Port:       Unknown
  SFP Vendor Name:   FINISAR CORP.
  SFP Vendor P/N:    FTLF8529P4BCV-QM
  SFP Vendor Rev:    B
  SFP Serial No.:    P2SABCS
  SFP Connector:     LC

  • Rx 和 Tx 功率显示为 0.0 (uWatts) (对于光纤通道目标适配器,在 ASUP 的  FCP-Adapter.xml 日志下):

Rx : 0.0 (uWatts)
Tx : 0.0 (uWatts)

  • Rx 和 Tx 功率在两端(存储和交换机端)均为最佳。

port 9a
Rx : 623.0 (uWatts)
Tx : 1020.9 (uWatts)

Slot  9/Port  2:
RX Power:    -0.5    dBm (883.9uW) 
TX Power:    -1.6    dBm (697.3 uW) 

 

  • 在 CLI 上执行的 Network fcp adapter show 命令将运行状态报告为“链路已断开”

cluster::> network fcp adapter show
                     Connection  Port      Admin   Operational
Node         Adapter Established Address   Status  Status
------------ ------- ----------- --------- ------- -----------------------
cluster-node1
             0c      false       0         up      link not connected
cluster-node1
             0d      false       0         up      link not connected
cluster-node1
             1a      true        f0500     up      online
cluster-node1
             1b      true        0         up      link disconnected
cluster-node2
             0c      false       0         up      link not connected
cluster-node2
             0d      false       0         up      link not connected
cluster-node2
             1a      true        f0600     up      online
cluster-node2
             1b      true        f0600     up      online

  • 存储 HBA 端口仍然物理连接
  • 可以验证以下故障排除步骤以隔离问题:
    1. 验证 远程 SFP 运行状况并重启 端口,使用以下命令:

Cisco 示例:

switch# config terminal
switch(config)# interface fc <slot>/<port#>
switch(config)# show int fc <slot>/<port#> transceiver detail
switch(config-if)# shutdown
switch(config-if)# no shutdown

Brocade 示例:

switch:admin> sfpshow <index # OR slot/port #>
switch:admin> portdisable <index # OR slot/port #>
switch:admin> portenable <index # OR slot/port #>

  1. 执行 物理检查并重新插拔链路和 配线架组件。
  2. 重新插拔后重复端口重启过程。
  3. 更换/交换两端的组件,包括线缆和 SFP。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.