在 AFF A400、FAS8300、FAS8700 上报告没有风扇/PSU 时,节点关闭无法开机
适用于
- ONTAP 9
- AFF A400 / FAS8300 / FAS8700
问题描述
- 节点关闭/由合作伙伴接管
- 通过 BMC 的连接表示主机电源关闭,并尝试通电不执行任何操作(节点保持关闭状态)
- 控制平台连接显示无输出,但允许 CTRL-G 访问 BMC
- BMC 日志表示重复电压错误:
1 | 07/21/2022 | 07:04:26 | Voltage #0x5a | Lower Non-critical going low2 | 07/21/2022 | 07:04:26 | Voltage #0x5b | Lower Non-critical going low3 | 07/21/2022 | 07:04:26 | Current #0x5c | Lower Non-critical going low4 | 07/21/2022 | 07:04:26 | Current #0x5d | Lower Non-critical going low5 | 07/21/2022 | 07:04:26 | OEM #0x5e | Lower Non-critical going low6 | 07/21/2022 | 07:04:26 | OEM #0x5f | Lower Non-critical going low7 | 07/21/2022 | 07:04:26 | Temperature #0x61 | Lower Non-critical going low8 | 07/21/2022 | 07:04:26 | Fan #0x63 | Lower Non-critical going low- 接下来是实体丢失和风扇/PSU缺失,导致关机:
108 | 07/20/2022 | 20:04:50 | Entity Presence #0x97 | Absent | Asserted109 | 07/20/2022 | 20:04:50 | Entity Presence #0x99 | Absent | Asserted118 | 07/21/2022 | 02:30:13 | Power Unit #0xb6 | | Asserted | absent FRU: MID1_FRU MID2_FRU PSU1_FRU PSU2_FRU FANMODULE1_FRU FANMODULE2_FRU FANMODULE3_FRU119 | 07/21/2022 | 02:30:13 | Power Unit #0xb7 | | Asserted | absent FRU: MID1_FRU MID2_FRU PSU1_FRU PSU2_FRU FANMODULE1_FRU FANMODULE2_FRU FANMODULE3_FRU