适用场景

  • FAS8060
  • FAS8040

问题描述

  • 多个系统风扇出现故障。
  • EMS.log 显示 。

[?] Fri Dec 18 14:54:02 KST [node: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F1
[?] Fri Dec 18 14:54:02 KST [node: env_mgr: monitor.chassisFan.stop:alert]: Chassis fan contains at least one stopped fan: SysFan1 F1 (failed)
[?] Fri Dec 18 14:54:02 KST [node: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2
[?] Fri Dec 18 14:54:02 KST [node: env_mgr: monitor.chassisFan.stop:alert]: Chassis fan contains at least one stopped fan: SysFan1 F2 (failed)
[?] Fri Dec 18 14:54:02 KST [node: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[?] Fri Dec 18 14:54:16 KST [node: config_thread: raid.aggr.log.CP.count:debug]: params: {'aggregate_uuid': '0x7f14c792-401cfb6b-f2b4e0bf-4a66d2ac', 'CP_count': '9208063', 'aggregate_type': 'Aggregate', 'home_owner_name': 'node', 'home_owner_id': '537132046', 'aggregate_name': 'node_aggr0'}
[?] Fri Dec 18 14:54:20 KST [node: dsa_vmm: hamsg.connectSucceeded:debug]: params: {'remoteID': '66d64da6b0c111e68de8254a945fa7e2'}
[?] Fri Dec 18 14:54:32 KST [node: env_mgr: callhome.c.fan.fru.shut:error]: Call home for MULTIPLE CHASSIS FAN FAILED: System will shut down in 2 minutes
[?] Fri Dec 18 14:54:39 KST [node: vldb: rdb.ha.verified:notice]: Verified that cluster high availability (HA) is configured correctly, and that on-disk mailboxes are intact.
[?] Fri Dec 18 14:55:00 KST [node: monitor: monitor.globalStatus.critical:critical]: Multiple fans failed: Sysfan1 F2, Sysfan1 F1.
[?] Fri Dec 18 14:55:25 KST [node: dsa_vmm: hamsg.connectSucceeded:debug]: params: {'remoteID': '66d64da6b0c111e68de8254a945fa7e2'}
[?] Fri Dec 18 14:56:32 KST [node: statd: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.