跳转到主内容

出现 FAS2820 (DISK REDUNDANCY FAILED) 错误

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • FAS2820
  • ONTAP 9

问题描述

  • AutoSupport  (DISK REDUNDANCY FAILED) ERROR 从节点触发,导致两个节点的 HA 状态降级。

node-1: 

NetApp Release 9.14.1P6: Tue Jun 18 12:11:44 EDT 2024
   System ID: 0987654321 (node-1); partner ID: 0123456789 (node-2)
   System Serial Number: 95XXXXXXXXXX (node-1)
   System Rev: A6
   System Storage Configuration: Multi-Path HA 
<<<在问题之前,有Tri-Path HA
   System ACP Connectivity: Inband Active
   SAS2/SAS3 Mixed Stack Support: all
   All-Flash Optimized: false
   Capacity Optimized: false
 All SAN Array: false
   Backplane Part Number: DS21212
   Backplane Rev: 
   Backplane Serial Number: 792XXXXXXXXX

 

node-2: 

NetApp Release 9.14.1P6: Tue Jun 18 12:11:44 EDT 2024
   System ID: 0123456789 (node-2); partner ID: 0987654321 (node-1)
   System Serial Number: 95XXXXXXXXXX (node-2)
   System Rev: A6
   System Storage Configuration: Mixed-Path HA 
<<<在发布之前,有Tri-Path HA 
   System ACP Connectivity: Inband Active
   SAS2/SAS3 Mixed Stack Support: all
   All-Flash Optimized: false
   Capacity Optimized: false
 All SAN Array: false
   Backplane Part Number: DS21212
   Backplane Rev: 
   Backplane Serial Number: 792XXXXXXXXX

 

  • 检查环境后,连接到 node-2 的 SAS 电缆 [7] 显示为 disconnected,并显示状态为 <N/A>

 SAS cable information by element:
  [1] Internal connector
  [2] Internal connector
  [3] Vendor: Molex Inc.
    Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
    Serial number: 123456789  Part number: 112-00437+A0
  [4] Vendor: <N/A> (disconnected)
    Type: <N/A><N/A><N/A> ID: <N/A> Swaps: 0
    Serial number: <N/A> Part number: <N/A>
  [5] Internal connector
  [6] Internal connector
  [7] Vendor: <N/A> (disconnected) 
    Type: <N/A><N/A><N/A> ID: <N/A> Swaps: 0
    Serial number: <N/A> Part number: <N/A>
  [8] Vendor: <N/A> (disconnected)
    Type: <N/A><N/A><N/A> ID: <N/A> Swaps: 0
    Serial number: <N/A> Part number: <N/A>

  • disconnected 之前,供应商名称和类型显示正确。

   SAS cable information by element:
    [1] Internal connector
    [2] Internal connector
    [3] Vendor: Molex Inc.
      Type: MINI-SAS HD passive copper 2m  ID: 00  Swaps: 0
      Serial number: 123456789  Part number: 112-00437+A0
    [4] Vendor: <N/A> (disconnected)
      Type: <N/A><N/A><N/A> ID: <N/A> Swaps: 0
      Serial number: <N/A> Part number: <N/A>
    [5] Internal connector
    [6] Internal connector
    [7] Vendor: Amphenol
      Type: MINI-SAS HD passive copper 0.5-1.0m ID: 01  Swaps: 0
      Serial number: APF12345678901 Part number: 112-00435+A0
    [8] Vendor: <N/A> (disconnected)
      Type: <N/A><N/A><N/A> ID: <N/A> Swaps: 0
      Serial number: <N/A> Part number: <N/A>
   ACP installed element list: 1, 2; with error: none

  • FAS2820 控制器 A 上的 SAS 端口 [3] 和 [4] 分别被指定为 0b1 和 0b2 端口。
  • 同样,在 FAS2820 控制器 B 上,端口 [7] 和 [8] 被指定为 0b1 和 0b2 端口。
  • 某些路径或 IOM 在 SAS-EXPANDER-MAP 日志上不可见。

​​Expanders on channel 0a:
Level   1: WWN 500a09800f6e6b8d, ID  1, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B

Expanders on channel 0b:
Level   1: WWN 500a09800f7af03f, ID  0, Serial Number '   ****', Product 'DS21212IOM12G   ', Rev '0201', Slot A
Level   2: WWN 500a09800f6e6c4d, ID  7, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   3: WWN 500a09800f6e8335, ID  6, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   4: WWN 500a09800f6e6c65, ID  5, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   5: WWN 500a09800f6e6b81, ID  4, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   6: WWN 500a09800f6e6a99, ID  3, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   7: WWN 500a09800f6e68d5, ID  2, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Level   8: WWN 500a09800f6e3119, ID  1, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot A
Expanders on channel 0c:
Level   1: WWN 500a09800f7aeb3f, ID  0, Serial Number '   ****', Product 'DS21212IOM12G   ', Rev '0201', Slot B
Level   2: WWN 500a09800f6e32f5, ID  7, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B
Level   3: WWN 500a09800f6e6aa9, ID  6, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B
Level   4: WWN 500a09800f6e6a91, ID  5, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B
Level   5: WWN 500a09800f6e64bd, ID  4, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B
Level   6: WWN 500a09800f6e6c2d, ID  3, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B
Level   7: WWN 500a09800f6e8365, ID  2, Serial Number '   ****', Product 'DS21212IOM12   ', Rev '0202', Slot B

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.