跳转到主内容

FAS2820:解决 10Gbps 网络速度问题

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS2820
  • CiscoN3K-C3172TQ-10GT 交换机
  • ONTAP 9

问题描述

  • 当连接到 Cisco N3K-C3172TQ-10GT 交换机时,10Gbps 网络端口仅以 1Gbps 运行。
  • 初始连接显示 e1c 端口为 10Gbps。
    重新连接电缆后,速度降至 1Gbps。
    所有其他端口(e1a、e1b、e1c、e1d)也显示 1Gbps。

::> port show
 Node: Node-01
        Speed(Mbps) Health
 Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
 --------- ------------ ---------------- ---- ---- ----------- --------
 a11l    Default    Datastore     up   1500    -/-    healthy
 e0M     Default    Default      up   1500  auto/1000  healthy
 e0a     Cluster    Cluster      up   9000  auto/25000 healthy
 e0b     Cluster    Cluster      up   9000  auto/25000 healthy
 e1a     Default    Service      up   1500  auto/1000 healthy
 e1b     Default    CAE        up   1500  auto/1000  healthy
 e1c     Default    -         up   1500 auto/1000 healthy 
 e1d     Default    -         up   1500 auto/1000 healthy
 Node: Node-02
                 Speed(Mbps) Health
 Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
 --------- ------------ ---------------- ---- ---- ----------- --------
 a21l    Default    Datastore     up   1500    -/- healthy
 e0M     Default    Default      up   1500  auto/1000  healthy
 e0a     Cluster    Cluster      up   9000  auto/25000 healthy
 e0b     Cluster    Cluster      up   9000  auto/25000 healthy
 e1a     Default    Service      up   1500  auto/1000 healthy
 e1b     Default    CAE        up   1500  auto/1000 healthy
 e1c     Default    -         up   1500  auto/1000 healthy
 e1d     Default    -         up   1500  auto/1000 healthy
 16 entries were displayed.

  • 相关网络接口也会在 sysconfig-a 日志中显示 1Gbps 的网速。

slot 1: 1/10 Gigabit Ethernet Controller IX4-T
 e1c MAC Address:   d0:39:ea:d4:16:** (auto-1000t-fd-up)
 e1d MAC Address:   d0:39:ea:d4:16:** (auto-1000t-fd-up)
 e1a MAC Address:   d0:39:ea:d4:16:** (auto-1000t-fd-up)
 e1b MAC Address:   d0:39:ea:d4:16:** (auto-1000t-fd-up)
 Device Type:     X550(0x1563) (BSD99) rev1
 Firmware Version:   2.20-0.1 etid 8000174d 
 Part Number:     110-00751   
 Hardware Revision:  A0

  • 两个节点上的 e1b 端口之间的直接连接导致 10Gbps 速度。

::> port show
 Node: Node-01
        Speed(Mbps) Health
 Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
 --------- ------------ ---------------- ---- ---- ----------- --------
 a11l    Default    Datastore     up   1500    -/-    healthy
 e0M     Default    Default      up   1500  auto/1000  healthy
 e0a     Cluster    Cluster      up   9000  auto/25000 healthy
 e0b     Cluster    Cluster      up   9000  auto/25000 healthy
 e1a     Default    Service      up   1500  auto/1000 healthy
 e1b     Default    CAE        up   1500  auto/10000  healthy
 e1c     Default    -         up   1500 auto/1000 healthy 
 e1d     Default    -         up   1500 auto/1000 healthy
 Node: Node-02
                 Speed(Mbps) Health
 Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
 --------- ------------ ---------------- ---- ---- ----------- --------
 a21l    Default    Datastore     up   1500    -/- healthy
 e0M     Default    Default      up   1500  auto/1000  healthy
 e0a     Cluster    Cluster      up   9000  auto/25000 healthy
 e0b     Cluster    Cluster      up   9000  auto/25000 healthy
 e1a     Default    Service      up   1500  auto/1000 healthy
 e1b     Default    CAE        up   1500  auto/10000 healthy
 e1c     Default    -         up   1500  auto/1000 healthy
 e1d     Default    -         up   1500  auto/1000 healthy
 16 entries were displayed.

    Sign in to view the entire content of this KB article.

    New to NetApp?

    Learn more about our award-winning Support

    NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.