适用场景

  • NS224 磁盘架
  • ONTAP 9

问题描述

在对 [1] AFF 型号执行启动设备更换操作步骤 后,节点将返回到等待交还状态;但是,控制台上会持续显示以下消息。

  • 在对AFF型号执行启动设备更换操作步骤之后、ONTAP无法启动。控制台上会持续显示以下消息:

Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Waiting for giveback...(Press Ctrl-C to abort wait)
Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
This node was previously declared dead.
Pausing to check HA partner status ...
lock was released, continuing boot ...
WARNING: 0 disks found!
WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)

  • 命令""disk show -v将生成以下内容:

*> disk show -v
 Local System ID: ********
disk show: No disks attached to system.
*> 

  • 命令""storage port show显示端口状态为disabled:

*> storage port show
 Port  Type   Speed(Gb/s)   State       Status   VLAN ID  Is Dedicated?
---------------------------------------------------------------------------
e0c   ENET   100 Gb/s    disabled      online   0     false    
e0d   ENET   100 Gb/s    disabled      online   0     false    
e5a   ENET   100 Gb/s    disabled      online   0     false    
e5b   ENET   100 Gb/s    disabled      online   0     false 

Entering FM state:5 because mbFound:0 local in headswap:0

查看 clustershell 中的 storage failover show 输出会将状态问题描述 显示为 "Kernel loaded" :

                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------
cluster1-01   cluster1-02 true    Connected to cluster1-02
cluster1-02   cluster1-01 true    Kernel loaded
2 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.