跳转到主内容

EMS 在 AFF A700s 系统上的多个机箱传感器上引发错误

Views:
25
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • AFF-A700
  • ONTAP 9.3P8
  • ONTAP 9.3P11

问题描述

在 AFF A700s 系统上, ONTAP 读取板载传感器的传感器值不正确,可能导致 ONTAP 报告多个传感器上的错误。

EMS 日志会引发:

EMERGENCY monitor.globalStatus.critical: Chassis temperature is too low.

Chassis temperature is too cool: NVMe1 Temp is critical low (-91 C).

ALERT monitor.chassisTemperature.cool: Chassis temperature is too cool: RiserL LTemp1 is critical low (-48 C).

Chassis temperature is too warm: CPU0 Temp is critical high (39 C).

Chassis power supply 1 is degraded: PSU1 InVoltage is Critical Low (72000 mV)

Chassis power is degraded: Sensor detecting voltage anomalies.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.