跳转到主内容

node_name 无法进行紧急控制器故障转移。日志未同步

Views:
110
Visibility:
Public
Votes:
1
Category:
aff-series<a>未同步日志</a><a>2008723333</a><a>ic6a</a><a>BURT 1396573</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A700
  • FAS9000
  • ONTAP 9

问题描述

  • EMS紧急消息:
Sun Apr 18 09:50:00 +0200 [node_name_1: monitor: monitor.globalStatus.critical:EMERGENCY]: Controller failover of node_name_2 is not possible: unsynchronized log.
  • 这是一个瞬时问题描述、不是永久性的。
  • 已启用存储故障转移。
  • 系统运行状况良好、不存在运行状况警报。
  • 事件日志示例:
Time        Node     Severity Event
----------------- ---------  -------  -------------------------------
4/8/2021 08:29:18 node_name_1 ERROR   cf.fsm.takeoverByPartnerDisabled: Failover monitor: takeover of node_name_1 by node_name_2 disabled (unsynchronized log).
4/8/2021 08:29:18 node_name_1 ERROR   cf.fsm.takeoverOfPartnerDisabled: Failover monitor: takeover of node_name_2 disabled (unsynchronized log).
4/8/2021 08:29:16 node_name_1 ERROR   cf.fsm.takeoverOfPartnerDisabled: Failover monitor: takeover of node_name_2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
4/8/2021 08:29:15 node_name_1 ERROR   cf.fsm.takeoverByPartnerDisabled: Failover monitor: takeover of node_name_1 by node_name_2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
4/8/2021 07:49:11 node_name_1 ERROR   cf.fsm.takeoverByPartnerDisabled: Failover monitor: takeover of node_name_1 by node_name_2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
4/8/2021 07:49:11 node_name_1 ERROR   cf.fsm.takeoverOfPartnerDisabled: Failover monitor: takeover of node_name_2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
  • 在两个节点中对互连链路问题描述进行转接:
Sun Apr 18 07:47:41 +0200 [node_name_1: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
Sun Apr 18 07:47:44 +0200 [node_name_1: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
Sun Apr 18 09:49:46 +0200 [node_name_1: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
Sun Apr 18 09:49:49 +0200 [node_name_1: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
...
 
Sun Apr 18 07:47:41 +0200 [node_name_2: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
Sun Apr 18 07:47:44 +0200 [node_name_2: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
Sun Apr 18 09:49:46 +0200 [node_name_2: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is down.
Sun Apr 18 09:49:49 +0200 [node_name_2: gop_eq_thread: ic.linkStatusChange:info]: HA interconnect: Port ic6a link is up.
...(英文)。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.