问题

  • 系统中缺少一个抽屉上的所有驱动器
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_n2_root/plex0/rg0/0a.10.51 Shelf 10 Drawer 5 Slot 3 Bay 51 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C254217C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25420D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.50 Shelf 10 Drawer 5 Slot 2 Bay 50 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25072D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.52 Shelf 10 Drawer 5 Slot 4 Bay 52 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559CB0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
  • HA 对中的一个或两个节点可能会因多磁盘死机而重新启动
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: cf.multidisk.fatalProblem:error]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr2: raid volfsm, fatal multi-disk error..  Raid type - raid_tec Group name plex0/rg0 state NORMAL. 6 disks failed in the group. Disk /aggr2/plex0/rg0/0a.10.58 Shelf 10 Drawer 5 Slot 10 Bay 58 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C250C3CC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk /aggr2/plex0/rg0/0a.10.55 Shelf 10 Drawer 5 Slot 7 Bay 55 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559D28:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk 0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49.
  • sysconfig -a 将显示架子上缺少 12 个驱动器。  DS460C 机架上有 60 个驱动器(0-59)。
    • 抽屉 1 包含驱动器 0-11
    • 抽屉 2 包含驱动器 12-23
    • 抽屉 3 包含驱动器 24-35
    • 抽屉 4 包含驱动器 36-47
    • 抽屉 5 包含驱动器 48-59
  • 从 sysconfig -a
10.38: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.39: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.40: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.41: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.42: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.43: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.44: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.45: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.46: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.47: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
<<missing>>
11.0: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
 
  • 检查 storage shelf drawer show 命令或 AutoSupport 部分 STORAGE-SHELF-DRAWER.XML 的输出,以确定缺少的抽屉详细信息。

    • 状态 A 和状态 B 将报告丢失抽屉的 Critical。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.