适用场景

  • DS460C 磁盘架
  • ONTAP 9

问题描述

  • 一个抽盒上的所有驱动器都从系统中丢失
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_n2_root/plex0/rg0/0a.10.51 Shelf 10 Drawer 5 Slot 3 Bay 51 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C254217C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25420D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.50 Shelf 10 Drawer 5 Slot 2 Bay 50 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C25072D4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex0/rg0/0a.10.52 Shelf 10 Drawer 5 Slot 4 Bay 52 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559CB0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
  • 由于多磁盘崩溃、HA对中的一个或两个节点可能会重新启动
Tue Feb 22 14:46:06 +0000 [node-01: config_thread: cf.multidisk.fatalProblem:error]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr2: raid volfsm, fatal multi-disk error..  Raid type - raid_tec Group name plex0/rg0 state NORMAL. 6 disks failed in the group. Disk /aggr2/plex0/rg0/0a.10.58 Shelf 10 Drawer 5 Slot 10 Bay 58 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C250C3CC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk /aggr2/plex0/rg0/0a.10.55 Shelf 10 Drawer 5 Slot 7 Bay 55 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2559D28:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.10.48 Shelf 10 Drawer 5 Slot 0 Bay 48 [NETAPP   X376_WVELE08TA07 NA01] S/N [XXXXXXXX] UID [5000CCA0:C2554E84:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk 0a.10.49 Shelf 10 Drawer 5 Slot 1 Bay 49.
  • sysconfig -a 将显示磁盘架中缺少12个驱动器。  一个DS460C磁盘架上有60个驱动器(0-59)。
    • 抽盒1包含0-11驱动器
    • 抽盒2包含驱动器12-23
    • 抽屉3包含24-35个驱动器
    • 抽屉4包含驱动器36-47
    • 抽屉5包含48-59驱动器
  • 从Sysconfig -a
10.38: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.39: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.40: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.41: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.42: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.43: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.44: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.45: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.46: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
10.47: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
<<missing>>
11.0: NETAPP   X376_WVELE08TA07 NA01 7486.1GB 520B/sect (XXXXXXXX)
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.