磁盘架机箱状态报告为备用电源
适用场景
- AFF和 FAS系统
- ONTAP 9
- DS212C磁盘架
问题描述
- 磁盘架机箱状态报告 为待机电源
::> system node run -node Node-01 -command storage show fault
Enclosure Status: standby power
Channel: 0a
Shelf: 12
Shelf Type: DS212-12
Product Serial Number: SHXXXXXXXXXXXX
Module Type: IOM12B
Vendor Unique Element 83-IOM12B: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12B A] : CRITICAL 02,88,00,93 MASTER, ADDITIONAL STATUS AVAILABLE, REFERENCE CLOCK FAULT, INTERNAL REGISTER FAULT, RESERVED, RESERVED
2 [IOM12B B] : CRITICAL 02,80,00,93 ADDITIONAL STATUS AVAILABLE, REFERENCE CLOCK FAULT, INTERNAL REGISTER FAULT, RESERVED, RESERVED
- 事件日志中会显示以下警报:
[Node-01: dsa_worker4: ses.status.ModuleError:alert]: DS212-12 (S/N SHXXXXXXXXXXXX) shelf 12 on channel 0a SAS expander error for SAS shelf electronics 1: critical status; Reference Clock Failure. This module is on the rear of the shelf at the top left, on shelf module A.