跳转到主内容

中的磁盘冗余失败错误和 SAS 速度错误 磁盘托架

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

控制器机箱中的内部磁盘架

问题

  • 磁盘被一个路径绕过。
  • 存储故障显示示例: 
Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: SHFHU0123456789
Module Type: IOM12E
Disk Elements:
Element Status Status Bytes Status Descriptions
0 [Bay 0]: OK 01,00,00,00
1 [Bay 1]: OK 01,01,00,00
2 [Bay 2]: OK 01,02,00,00
3 [Bay 3]: OK 01,03,00,00
4 [Bay 4]: NONCRITICAL 03,04,10,04 ENCLOSURE BYPASSED B, BYPASSED B
  • 缺少磁盘 0b.00.4 :

*> disk_list
   DISK   CHAN  VENDOR   PRODUCT ID     REV  SERIAL#        HW (BLOCKS   BPS) DQ
------------ ----- -------- ---------------- ---- -------------------- -- -------------- --
0b.00.3     SA:B NETAPP   X336_TTCRE04TA07 NA03 012345678910     ff 7814037168  520  N
0b.00.7     SA:B NETAPP   X336_TTCRE04TA07 NA03 012345678911     ff 7814037168  520  N
...

  • 重新拔插 / 更换不会修复问题描述:

Mon Feb 01 23:01:05 +0100 [node_name: dmgr_thread: raid.disk.inserted:info]: Disk 0a.00.4 Shelf 0 Bay 4 [NETAPP   X336_SMBPE04TA07 NA00] S/N [01234567] UID [5000C500:B716BB57:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
Tue Feb 02 14:34:30 +0100 [node_name: dsa_worker0: ds.sas.drivephy.disableErr:error]: Disk  [NETAPP  :X336_HAKPE04TA07:NA00] S/N [01234567]  on channels 0b shelf ID 0 IOM B bay 4 disabled due to excessive invalid dword error.

  • 磁盘在该路径中显示无效词:

Shelf name:   0b.shelf0
Shelf id:    0
Channel:     0b
Module:     B
Shelf UID:    50:aa:a:aa:aa:aa:aa:aa
Shelf S/N:    SHFHU0123456789
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

        Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk   Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id    State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
...
[  4 ] DIS/INVWD   7      NA    1454     1175     0     0      0     5

  • 该托架中的速度错误:

Shelf name:   0a.shelf0
Shelf id:    0
Channel:     0a
Module:     B
Shelf UID:    50:aa:aa:aa:aa:aa:aa:aa
Shelf S/N:    SHFHU0123456789
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK

        Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk   Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id    State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
...
[  3 ] OK        7     12.0     0       0     0     0      0     1
[  4 ] OK        7     1.5    0       0     0     0      0     6
[  5 ] OK        7     12.0     0       0     0     0      0     1
...

 

 
 
 
 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.