磁盘仅在NS224磁盘架上显示一个路径(磁盘冗余错误)
适用场景
- ONTAP 9
- NS224 (NSM100)
问题描述
- 磁盘X.XX.XX仅显示一个路径。如果磁盘冗余失败、Data ONTAP将触发回呼
- 两个节点上的一个路径上缺少驱动器、如下图所示:
ClusterA-01::> sysconfig -a
e1a MAC Address: d0:00:aa:00:00:00 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486860
01.0.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.0.1: NETAPP X4011S172B3T8NTE NA56 3662.5GB 4160B/sect (S57YXXXXXXXXXX)
01.0.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.0.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
e1b MAC Address: d0:39:ea:49:13:41 (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486668
01.3.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
<No Drive 1 listed here as expected>
01.3.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.3.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
ClusterA-02::> sysconfig -a
e1a MAC Address: d0:39:ea:XX:XX:XX(auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21419478411
01.2.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
<No Drive 1 listed here as expected>
01.2.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.2.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
e1b MAC Address: d0:39:ea:XX:XX:XX (auto-100g_cr4-fd-up)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00574
QSFP Serial Number: APF21429486707
01.1.0: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.1.1: NETAPP X4011S172B3T8NTE NA56 3662.5GB 4160B/sect (S57YXXXXXXXXXX)
01.1.2: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
01.1.3: NETAPP X4011S17333T8NTE NA53 3662.5GB 4160B/sect (S60NXXXXXXXXXX)
- 有时、磁盘可能会完全丢失。如果文件系统磁盘缺失、Data ONTAP将触发回调