跳转到主内容

磁盘维护超过 24 小时

Views:
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
generalsupport
Last Updated:

适用场景

ONTAP 9

问题描述

发生故障的磁盘进入维护状态,并且在 24 小时内不会发生故障或返回备用池。
 
从 EMS 日志中我们看到:
 
Fri May 23 17:57:46 -0500 [node-01: config_thread: raid.disk.maint.start:notice]: Disk 0a.02.38 Shelf 2 Drawer 4 Slot 2 Bay 38 [NETAPP   X378_HLBRE10TA07 NA03] S/N [XXXXXX] UID [5000CCA2:A24AC8E4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] will be tested.
Fri May 23 17:57:46 -0500 [nnode-01: disk_admin: disk.outOfService:notice]: Drive 0a.02.38 (XXXXXX): non-persistent message received. Power-On Hours: 33517, GList Count: 14, Drive Info: Disk 0a.02.38 Shelf 2 Drawer 4 Slot 2 Bay 38 [NETAPP   X378_HLBRE10TA07 NA03] S/N [4DHA3ZYZ] UID [5000CCA2:A24AC8E4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000].
Fri May 23 17:59:05 -0500 [node-01: sanown_io: diskown.errorReadingOwnership:notice]: error 43 (disk is in maintenance testing) while reading ownership on disk 0a.02.38 (S/N XXXXX)
Fri May 23 17:59:05 -0500 [node-01: sanown_io: diskown.statusReadOwnership:info]: params: {'errorno': '43', 'errortext': 'disk is in maintenance testing', 'diskname': '0a.02.38', 'serialno': 'XXXXXX'}
Fri May 23 17:59:15 -0500 [node-01: sanown_io: diskown.errorDuringIO:error]: error 13 (fatal disk error) on disk 0a.02.38 (S/N XXXXXX) while setting disk reservation
Fri May 23 19:42:29 -0500 [node-01: sanown_io: diskown.errorReadingOwnership:notice]: error 43 (disk is in maintenance testing) while reading ownership on disk 0a.02.38 (S/N XXXXX)
Fri May 23 19:42:29 -0500 [node-01: sanown_io: diskown.statusReadOwnership:info]: params: {'errorno': '43', 'errortext': 'disk is in maintenance testing', 'diskname': '0a.02.38', 'serialno': 'XXXXX'}
 
Mon May 26 23:00:38 -0500 [node-01: disk_maint_admin: disk.maint.test.end:notice]: Disk 0a.02.38 Model [X378_HLBRE10TA07] S/N [XXXX] has completed maintenance testing with status 0 (0x0,0x0,0x0,0x0).
Mon May 26 23:00:39 -0500 [node-01: config_thread: raid.disk.maint.done:notice]: Disk 0a.02.38 Shelf 2 Drawer 4 Slot 2 Bay 38 [NETAPP   X378_HLBRE10TA07 NA03] S/N [XXXXXX] UID [5000CCA2:A24AC8E4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] tests were completed successfully.

 

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.