磁盘架固件升级后出现磁盘冗余故障错误
适用场景
FAS8300、 AFF-A700
 问题描述
- 磁盘架固件 升级后、系统位于混合路径中
 
SYSCONFIG-A
System Serial Number: YYYYYYYYYYYYSystem Storage Configuration: Multi-Path HASystem Serial Number: XXXXXXXXXXXXSystem Storage Configuration: Mixed-Path HAslot 1: SAS Host Adapter 1d (Broadcom SAS3616W rev. 2, SAS, <UP>)Phy State:[0] Enabled, 12.0 Gb/s    [1] Enabled, 12.0 Gb/s    [2] Enabled, 12.0 Gb/s    [3] Enabled, 12.0 Gb/sMini-SAS HD Vendor:     Molex Inc.Mini-SAS HD Part Number:  112-00437 A0Mini-SAS HD Type:      Passive Copper (unequalized) 2m end_1Mini-SAS HD Serial Number: XXXXXXXX00.33: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)00.34: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)00.35: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)00.48: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)00.49: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)00.50: NETAPP  X377_WVAXE10TA07 NA02 9324.2GB 520B/sect (XXXXXXXX)EMS-LOG-FILE.GZ
Tue Feb 06 09:28:03 -0500 [nodexxxx: svc_queue_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.Tue Feb 06 09:28:03 -0500 [nodexxxx: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED- 在上述示例中、节点的适配器1d无法检测到磁盘架0的抽盒4
- 连接到这两个 节点的所有其他适配器都会检测到同一抽盒