节点重新启动期间、插槽中的设备随机丢失
适用场景
- ONTAP 9
- FAS/AFA系统
问题描述
- 在节点重新启动期间随机显示以下消息:
Configuring Devices ...
Device(s) in slot missing, attempting to recover it.
System is resetting.
- 配对节点不具有相同的问题描述。
- 此消息发生在中
SP-LATEST-SYSTEM-EVENT-LOG
Record 196: Fri Oct 28 03:52:24.000000 2022 [SysFW.notice]: Device 207/0/0 (SLOT-10) missing
Record 197: Fri Oct 28 03:52:27.000000 2022 [SysFW.notice]: Device(s) in slot missing, attempting to recover it.
Record 198: Fri Oct 28 03:52:32.488955 2022 [SP.notice]: PCIE Config Info received from BIOS
Record 199: Fri Oct 28 03:52:32.502057 2022 [SP.notice]: ScratchPad Config Info received from BIOS
- 请注意、节点启动后缺少扩展卡:
重新启动前:
sysconfig: slot 1 OK: X1117A: Intel Dual 10G IX1-SFP NIC
sysconfig: slot 2 OK: X1133A: Broadcom LPE16004; Quad-Port 16Gb FC Adapter (PCIe)
sysconfig: No shelf configuration errors detected.
sysconfig: There are no configuration errors.
重新启动后:
sysconfig: slot 1 OK: X1117A: Intel Dual 10G IX1-SFP NIC
sysconfig: No shelf configuration errors detected. <<<<<<<<<<<slot 2 card missing
sysconfig: There are no configuration errors.
- 如果将缺少的卡用于存储、则节点可能会从"多路径"过渡到"单路径"、或者从"四路径"过渡到"多路径"。