检测到Bug1063994固定版本中的电池充电FET关闭警报
适用场景
- FAS2650
- ONTAP 9
- 服务处理器 (SP)
问题描述
- 系统将触发(蓄电池(充电FET关闭))警报。
HA Group Notification from node-1 (BATTERY (charge FET off)) ALERT
EMS 日志:
Thu Aug 24 04:41:21 JST [node-1: env_mgr: nvmem.battery.FET.off:debug]: The NVMEM battery charge FET is off. To prevent data loss, the system will shut down in 24 hours.
Thu Aug 24 04:41:32 JST [node-1: env_mgr: nvmem.battery.tempLow:debug]: The NVMEM battery is too cold (-17 C). To prevent data loss, the system will shut down in 24 hours.
Thu Aug 24 04:41:54 JST [node-1: env_mgr: nvmem.battery.temp.normal:debug]: The NVMEM battery temperature is normal.
Thu Aug 24 04:41:54 JST [node-1: env_mgr: nvmem.battery.packValid:debug]: A valid NVMEM battery pack is present.
Thu Aug 24 04:42:06 JST [node-1: env_mgr: nvmem.battery.FET.normal:debug]: The NVMEM battery charge FET is on.
Thu Aug 24 04:42:24 JST [node-1: env_mgr: callhome.battery.warning:debug]: Call home for BATTERY (charge FET off) WARNING.
- 在相应时间段内未执行任何学习周期。
LrnCycleStartDate :
23-07-21-12:00
LrnCycleStartFCC : 0x0560
LrnCycleEndFCC : 0x0556
LrnCycleEndDate :
23-07-21-23:3
- 服务处理器(SP)版本为SP5.3、即 错误编号1063994 固定版本。