::> system health alert show
         Node: node01
       Alert ID: DegradedOnlineShelfPort_Alert
       Resource: Shelf 1.13
    Probable Cause: Shelf-to-shelf connection between disk shelves 1.13 1
            port and 1.12 3 port have 1 inactive PHYs on IOM B.
    Possible Effect: Inactive PHYs might cause degraded link performance.
  Corrective Actions: 1. Consult the guide applicable to your IOM12B disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
            2. Verify that disk shelf 1.13 has disabled PHYs by using the "storage shelf show -shelf 1.13 -port" command.
            3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.13 1 port cable on IOM B and disk shelf 1.12 3 port cable on IOM B.
            4. Verify that the physical cable connection is secure
            and operational, and replace the cable, if necessary.
        Node: CJ4DXNASTMP2_node02
       Alert ID: DegradedOnlineShelfPort_Alert
       Resource: Shelf 1.13
    Probable Cause: Shelf-to-shelf connection between disk shelves 1.13 1
            port and 1.12 3 port have 1 inactive PHYs on IOM B.
    Possible Effect: Inactive PHYs might cause degraded link performance.
  Corrective Actions: 1. Consult the guide applicable to your IOM12B disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
            2. Verify that disk shelf 1.13 has disabled PHYs by using the "storage shelf show -shelf 1.13 -port" command.
            3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.13 1 port cable on IOM B and disk shelf 1.12 3 port cable on IOM B.
            4. Verify that the physical cable connection is secure
            and operational, and replace the cable, if necessary.
- 更换货架之间的电缆没有帮助。
 - 重新拔插 IOM 模块没有帮助。