固件升级后、DS460C磁盘架IOM报告降级
适用场景
问题描述
- 升级DS460C磁盘架的磁盘架固件后、IOM B将报告
NONCRITICAL
状态和PATH FAIL
- 自
EMS:
Mon Aug 14 14:09:54-0500 [node-01: hamsg: sfu.adapterSuspendIO.ndu:info]:Suspending SMP to SAS adapter 0a for 35 seconds while shelf firmware isupdated.
Mon Aug 14 14:10:56-0500 [node-01: hamsg: sfu.adapterSuspendIO.ndu:info]:Suspending SMP to SAS adapter 0d for 35 seconds while shelf firmware isupdated.
Mon Aug 14 14:12:46-0500 [node-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0a. Check fans, powersupplies, disks, and temperature sensors.
Mon Aug 14 14:13:00-0500 [node-01: monitor:monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
- 发件人
storage fault show
:
Enclosure Status:normal
Channel: 0a
Shelf: 10
Shelf Type: DS460-12
Product SerialNumber: SHJGDXXXXXXXXXX
Module Type: IOM12B
Drawers ControlModule:
Element Status StatusBytes Status Descriptions
1 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
2 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
3 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
4 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
5 [IOM12B A] : OK 01,00,01,01 REPORT, TYPE BIT0
6 [IOM12B B] : NONCRITICAL 03,00,11,01 REPORT,PATH FAIL, TYPE BIT0
7 [IOM12B B] : NONCRITICAL 03,00,11,01 REPORT,PATH FAIL, TYPE BIT0
8 [IOM12B B] : NONCRITICAL 03,00,11,01 REPORT,PATH FAIL, TYPE BIT0
9 [IOM12B B] : NONCRITICAL 03,00,11,01 REPORT,PATH FAIL, TYPE BIT0
10 [IOM12B B] : NONCRITICAL 03,00,11,01 REPORT,PATH FAIL, TYPE BIT0