跳转到主内容

固件升级后、DS460C磁盘架IOM报告降级

Views:
8
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009952936</a>
Specialty:
hw
Last Updated:

适用场景

DS460C磁盘架

问题描述

  • 升级DS460C磁盘架的磁盘架固件后、IOM B将报告 NONCRITICAL 状态和PATH FAIL
  • EMS:

Mon Aug 14 14:09:54-0500 [node-01: hamsg: sfu.adapterSuspendIO.ndu:info]:Suspending SMP to SAS adapter 0a for 35 seconds while shelf firmware isupdated.

Mon Aug 14 14:10:56-0500 [node-01: hamsg: sfu.adapterSuspendIO.ndu:info]:Suspending SMP to SAS adapter 0d for 35 seconds while shelf firmware isupdated.

Mon Aug 14 14:12:46-0500 [node-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0a. Check fans, powersupplies, disks, and temperature sensors.

Mon Aug 14 14:13:00-0500 [node-01: monitor:monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.

  • 发件人 storage fault show
Enclosure Status:normal

Channel: 0a

Shelf: 10

Shelf Type: DS460-12

Product SerialNumber: SHJGDXXXXXXXXXX

Module Type: IOM12B

 

Drawers ControlModule:

Element Status            StatusBytes  Status Descriptions

1 [IOM12B A]   : OK        01,00,01,01  REPORT, TYPE BIT0

2 [IOM12B A]   : OK        01,00,01,01  REPORT, TYPE BIT0

3 [IOM12B A]   : OK        01,00,01,01  REPORT, TYPE BIT0

4 [IOM12B A]   : OK        01,00,01,01  REPORT, TYPE BIT0

5 [IOM12B A]   : OK        01,00,01,01  REPORT, TYPE BIT0

6 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT,PATH FAIL, TYPE BIT0

7 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT,PATH FAIL, TYPE BIT0

8 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT,PATH FAIL, TYPE BIT0

9 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT,PATH FAIL, TYPE BIT0

10 [IOM12B B]   : NONCRITICAL    03,00,11,01  REPORT,PATH FAIL, TYPE BIT0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.