DS460C 报告 HOST_PORT_FAIL - 由 IOM 禁用
适用于
- DS460C (DS460-12)
- IOM12
问题描述
- EMS 报告 HOST_PORT_FAIL - 由 IOM 禁用
12/23/2022 09:00:00 node-02 ALERT monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.12/23/2022 09:00:00 node-02 INFORMATIONAL kern.uptime.filer: 9:00am up 259 days, 23:42 96 NFS ops, 0 CIFS ops, 0 HTTP ops, 0 FCP ops, 0 iSCSI ops, 0 NVMF ops12/23/2022 09:00:00 node-03 INFORMATIONAL kern.uptime.filer: 9:00am up 259 days, 22:34 93 NFS ops, 0 CIFS ops, 0 HTTP ops, 0 FCP ops, 0 iSCSI ops, 0 NVMF ops12/23/2022 09:00:00 node-04 INFORMATIONAL kern.uptime.filer: 9:00am up 259 days, 22:57 2535283 NFS ops, 0 CIFS ops, 0 HTTP ops, 0 FCP ops, 0 iSCSI ops, 0 NVMF ops12/23/2022 08:49:27 node-02 ALERT ses.shelf.drwr.phy.rateunkwn: Drive shelf 20, module B, drawer 2, PHY 0 is reporting an unknown link rate.12/23/2022 08:40:13 node-01 ALERT ses.shelf.drwr.phy.rateunkwn: Drive shelf 20, module B, drawer 2, PHY 0 is reporting an unknown link rate.12/23/2022 08:38:32 node-02 INFORMATIONAL noderun.login.success: 'admin' logged in from cluster: 'cluster'.12/23/2022 08:37:34 node-01 INFORMATIONAL noderun.login.success: 'admin' logged in from cluster: 'cluster'.12/23/2022 08:34:15 node-02 ALERT callhome.hostport.disable: Call home for HOST_PORT_FAIL - Disabled by IOM12/23/2022 08:34:15 node-02 ALERT ds.sas.hostphy.disableErr: Port [DCM2-1] on channels 0c shelf ID 20 IOM B disabled due to excessive phy changes. 12/23/2022 08:33:57 node-02 INFORMATIONAL sas.adapter.debug: adapterName="0a", debug_string="Asyncd device scan done."- 存储故障显示中 DCM 出现故障
Drawers Control Module:Element Status Status Bytes Status Descriptions1 [IOM12 A] : OK 01,00,01,00 REPORT2 [IOM12 A] : OK 01,00,01,00 REPORT3 [IOM12 A] : OK 01,00,01,00 REPORT4 [IOM12 A] : OK 01,00,01,00 REPORT5 [IOM12 A] : OK 01,00,01,00 REPORT6 [IOM12 B] : OK 01,00,01,00 REPORT7 [IOM12 B] : CRITICAL 02,40,00,00 FAIL8 [IOM12 B] : OK 01,00,01,00 REPORT9 [IOM12 B] : OK 01,00,01,00 REPORT10 [IOM12 B] : OK 01,00,01,00 REPORTVendor Unique Element 83-IOM12: (SAS)Element Status Status Bytes Status Descriptions1 [IOM12 A] : OK 01,08,00,20 MASTER, RESERVED2 [IOM12 B] : OK 01,00,00,20 RESERVED